摘要
Stridor is one of the most frequent causes of early extubation failure. The cuff-leak test may help to identify patients at risk to develop post-extubation laryngeal edema. However the discrimination power of the cuff-leak test is highly variable and can be use, at best, to detect patients at risk to develop edema but should not be used to postpone extubation as tracheal extubation can still be successful in many patients with a positive test. In this editorial, the author discuss the factors influencing the leak and hence its predictive value.
引用
收藏
页码:31 / 33
页数:3
相关论文
共 12 条
[1]   WHEN TO EXTUBATE THE CROUP PATIENT - THE LEAK TEST [J].
ADDERLEY, RJ ;
MULLINS, GC .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1987, 34 (03) :304-306
[2]   Reintubation as an outcome predictor in trauma patients [J].
Daley, BJ ;
GarciaPerez, F ;
Ross, SE .
CHEST, 1996, 110 (06) :1577-1580
[3]   The cuff leak test to predict failure of tracheal extubation for laryngeal edema [J].
De Bast, Y ;
De Backer, D ;
Moraine, JJ ;
Lemaire, M ;
Vandenborght, U ;
Vincent, JL .
INTENSIVE CARE MEDICINE, 2002, 28 (09) :1267-1272
[4]   Evaluation of the cuff-leak test in a cardiac surgery population [J].
Engoren, M .
CHEST, 1999, 116 (04) :1029-1031
[5]   Independent effects of etiology of failure and time to reintubation on outcome for patients failing extubation [J].
Epstein, SK ;
Ciubotaru, RL .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1998, 158 (02) :489-493
[6]   Extubation outcome after spontaneous breathing trials with T-tube or pressure support ventilation [J].
Esteban, A ;
Alia, I ;
Gordo, F ;
Fernandez, R ;
Solsona, JF ;
Vallverdu, I ;
Macias, S ;
Allegue, M ;
Blanco, J ;
Carriedo, D ;
Leon, M ;
delaCal, MA ;
Taboada, F ;
deVelasco, JG ;
Palazon, E ;
Carrizosa, F ;
Tomas, R ;
Suarez, J ;
Goldwasser, RS .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1997, 156 (02) :459-465
[7]   THE CUFF-LEAK TEST FOR EXTUBATION [J].
FISHER, MM ;
RAPER, RF .
ANAESTHESIA, 1992, 47 (01) :10-12
[8]   Post-extubation stridor in intensive care unit patients - Risk factors evaluation and importance of the cuff-leak [J].
Jaber, S ;
Chanques, G ;
Matecki, S ;
Ramonatxo, M ;
Vergne, C ;
Souche, B ;
Perrigault, PF ;
Eledjam, JJ .
INTENSIVE CARE MEDICINE, 2003, 29 (01) :69-74
[9]   How to identify patients with no risk for postextubation stridor? [J].
Maury, E ;
Guglielminotti, J ;
Alzieu, M ;
Qureshi, T ;
Guidet, B ;
Offenstadt, G .
JOURNAL OF CRITICAL CARE, 2004, 19 (01) :23-28
[10]   Association between reduced cuff leak volume and postextubation stridor [J].
Miller, RL ;
Cole, RP .
CHEST, 1996, 110 (04) :1035-1040