Determination of 5-hydroxytryptamine (serotonin) and related indoles by flow injection analysis with acidic potassium permanganate chemiluminescence detection

被引:71
作者
Barnett, NW [1 ]
Hindson, BJ [1 ]
Lewis, SW [1 ]
机构
[1] Deakin Univ, Sch Biol & Chem Sci, Geelong, Vic 3217, Australia
关键词
chemiluminescence; detection; flow injection analysis; 5-hydroxytryptamine; serotonin; 5-hydroxytryptophan; 5-hydroxyindole-3-acetic acid;
D O I
10.1016/S0003-2670(98)00058-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple, rapid and sensitive method for the determination of 5-hydroxytryptamine (serotonin), 5-hydroxytryptophan or 5-hydroxyindole-3-acetic acid, using flow injection analysis with acidic potassium permanganate chemiluminescence detection, is described. The log-log plots for 5-hydroxytryptamine, 5-hydroxytryptophan and 5-hydroxyindole-3-acetic acid gave equations of best fit, of y=-0.03x(2)+0.51x+6.15 (r(2)=0.9990), y=-0.05x(2)+0.35x+5.70 (r(2)=0.9995) and y=-0.04x(2)+0.49x+5.60 (r(2)=0.9999) respectively, where y is log (chemiluminescence emission response (mV)) and x is log (concentration (M)). The log-log calibration functions for the three analytes approximated linearity in the concentration range from 1x10(-8) to 1x10(-6) M, where the slopes of the log-log plots were within the range from 1.01 to 1.04. The precision (measured as relative standard deviation) for 5-hydroxytryptamine was 2.3% (n=6 at 1x10(-7) M). The detection limits (signal-to-noise ratio=3) were 2x10(-9) M, 3x10(-9) M and 1.5x10(-8) M for 5-hydroxytryptamine, 5-hydroxytryptophan and 5-hydroxyindole-3-acetic acid, respectively. Preliminary experiments using an extended range photomultiplier tube realised enhanced detection limits due to the wavelength of maximum emission being centered around 670 nm rather than 610 nm as previously thought. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:131 / 139
页数:9
相关论文
共 34 条
[1]  
ABBOTT R W, 1986, Analytical Proceedings, V23, P25
[2]   DETERMINATION OF MORPHINE IN BODY-FLUIDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH CHEMILUMINESCENCE DETECTION [J].
ABBOTT, RW ;
TOWNSHEND, A ;
GILL, R .
ANALYST, 1987, 112 (04) :397-406
[3]   DETERMINATION OF MORPHINE BY FLOW-INJECTION ANALYSIS WITH CHEMILUMINESCENCE DETECTION [J].
ABBOTT, RW ;
TOWNSHEND, A ;
GILL, R .
ANALYST, 1986, 111 (06) :635-640
[4]   Determination of carbohydrates by flow injection with direct chemiluminescence detection [J].
Agater, IB ;
Jewsbury, RA ;
Williams, K .
ANALYTICAL COMMUNICATIONS, 1996, 33 (10) :367-369
[5]  
AGATER IB, 1997, COMMUNICATION
[6]  
AHMED TEA, 1994, ANAL CHIM ACTA, V292, P169
[7]   FLOW-INJECTION CHEMILUMINESCENCE DETERMINATION OF SULFITE [J].
ALTAMRAH, SA ;
TOWNSHEND, A ;
WHEATLEY, AR .
ANALYST, 1987, 112 (06) :883-886
[8]   DETERMINATION OF NAPHTHOLS BY FLOW-INJECTION CHEMI-LUMINESCENCE [J].
ALTAMRAH, SA ;
TOWNSHEND, A .
ANALYTICA CHIMICA ACTA, 1987, 202 :247-250
[10]  
ALWARTHAN AA, 1986, ANAL CHIM ACTA, V202, P247