Catheter closure of perimembranous ventricular septal defects using the new amplatzer membranous VSD occluder: Initial clinical experience

被引:337
作者
Hijazi, ZM
Hakim, F
Abu Haweleh, A
Madani, A
Tarawna, W
Hiari, A
Cao, OL
机构
[1] Univ Chicago, Childrens Hosp, Dept Pediat, Pediat Cardiol Sect, Chicago, IL 60637 USA
[2] Queen Alia Heart Inst, Pediat Cardiol Sect, Amman, Jordan
[3] Queen Alia Heart Inst, Dept Anesthesia, Sect Cardiac Anesthesia & Crit Care, Amman, Jordan
关键词
ventricular septal defect; congenital heart disease; catheter closure;
D O I
10.1002/ccd.10292
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
The surgical closure of membranous ventricular septal defects (VSDs) is associated with morbidity and low mortality. Six patients with VSDs located in the membranous part of the ventricular septum underwent an attempt of catheter closure using a new device specifically designed for the membranous septum. Patients ranged in age from 3.5 to 19 years (median, 10.5 years) and in weight from 15 to 45 kg (median, 29 kg). One patient with associated pulmonary valve stenosis had shortness of breath. The median Qp/Qs ratio was 1.6 (range, 1.1-3) and the median left ventricle end-diastolic dimension (LVEDD) was 44 mm (range, 38-52 mm). The devices were deployed via the femoral vein using 7-8 Fr sheaths. There was immediate complete closure in all patients. One patient developed trivial aortic regurgitation. There were no other complications. The median fluoroscopy time was 15.5 min (range, 10.3-53.4 min). At 24 hr, all patients were doing well. The median LVEDD decreased to 38 mm (range, 34-47 mm). One patient continued to have trace aortic regurgitation. All patients were discharged home after 24 hr. Transcatheter occlusion of membranous VSDs is safe and effective. Further clinical trials are underway to assess the long-term safety and results.
引用
收藏
页码:508 / 515
页数:8
相关论文
共 11 条
[1]
RESTRICTIVE VENTRICULAR SEPTAL-DEFECT - HOW SMALL IS TOO SMALL TO CLOSE [J].
BACKER, CL ;
WINTERS, RC ;
ZALES, VR ;
TAKAMI, H ;
MUSTER, AJ ;
BENSON, DW ;
MAVROUDIS, C .
ANNALS OF THORACIC SURGERY, 1993, 56 (05) :1014-1019
[2]
Hijazi ZM, 2000, CATHETER CARDIO INTE, V49, P167, DOI 10.1002/(SICI)1522-726X(200002)49:2<167::AID-CCD11>3.0.CO
[3]
2-S
[4]
Transcatheter device closure of ventricular septal defects: Immediate results and intermediate-term follow-up [J].
Kalra, GS ;
Verma, PK ;
Dhall, A ;
Singh, S ;
Arora, R .
AMERICAN HEART JOURNAL, 1999, 138 (02) :339-344
[5]
KIDD L, 1993, CIRCULATION, V87, P138
[6]
Masura J, 1997, CATHETER CARDIO DIAG, V42, P388, DOI 10.1002/(SICI)1097-0304(199712)42:4<388::AID-CCD7>3.0.CO
[7]
2-7
[8]
Rudolph AM., 2001, CONGENITAL DIS HEART, P197
[9]
Occlusion of congenital ventricular septal defects by the buttoned device [J].
Sideris, EB ;
Walsh, KP ;
Haddad, JL ;
Chen, CR ;
Ren, SG ;
Kulkarni, H .
HEART, 1997, 77 (03) :276-279
[10]
Transcatheter closure of muscular ventricular septal defects with the Amplatzer ventricular septal defect occluder: Initial clinical applications in children [J].
Thanopoulos, BD ;
Tsaousis, GS ;
Konstadopoulou, GN ;
Zarayelyan, AG .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 33 (05) :1395-1399