NIR measurement of moisture content in wood under unstable temperature conditions. Part 2. Handling temperature fluctuations

被引:50
作者
Thygesen, LG [1 ]
Lundqvist, SO [1 ]
机构
[1] Swedish Pulp & Paper Res Inst, STFI, SE-11486 Stockholm, Sweden
关键词
near infrared (NIR) spectroscopy; temperature; moisture; wood; chemometrics; Partial Least Squares (PLS) regression;
D O I
10.1255/jnirs.278
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
Fluctuations in sample temperature cause peak shifts in near infrared (NIR) spectra of moist, solid wood samples, especially when the temperature varies around 0 degrees C (the freezing point of water). These thermal effects cannot be ignored when NIR and Partial Least Squares (PLS) regression is used for determination of the moisture content of mood outside the laboratory. In this paper, a number of different approaches to the problem are investigated. The approaches may be divided into two different classes according to their basic strategy. One strategy, the soft model strategy, is to represent all relevant temperatures in the calibration set and then produce a global model or a set of local models based on raw or pretreated spectra, This strategy does not require knowledge of the structure of the thermal effects, but a large calibration set representing all relevant temperatures is needed. Three approaches based on this strategy mere tested. The other strategy, the transformation strategy, is to develop the moisture content model at one temperature and transform spectra recorded at other temperatures to this temperature. If an effective transformation algorithm can be found, this strategy should require less calibration data, Four new approaches based on the transformation strategy were developed and tested. The three soft model approaches gave similar prediction errors (RMSEP) for unknown samples (8-9%, expressed as moisture ratio, i.e. the moisture content in percent of the dry weight), None of the approaches based on the transformation strategy gave smaller prediction errors than the soft model approaches, but two of them gave only slightly larger prediction errors (RMSEP) than the soft model approaches (9-10% moisture).
引用
收藏
页码:191 / 199
页数:9
相关论文
共 20 条
[1]  
[Anonymous], 1989, MULTIVARIATE CALIBRA
[2]  
[Anonymous], 1987, NEAR INFRARED TECHNO
[3]  
BUCHMANN NB, 1997, COMMUNICATION
[4]  
BUCHMANN NB, 1992, FOCUS TECATOR J TECH, V15, P12
[5]   VISIBLE AND NEAR-INFRARED REFLECTANCE CHARACTERISTICS OF DRY PLANT MATERIALS [J].
ELVIDGE, CD .
INTERNATIONAL JOURNAL OF REMOTE SENSING, 1990, 11 (10) :1775-1795
[6]   TEMPERATURE-INSENSITIVE NEAR-INFRARED SPECTROSCOPIC MEASUREMENT OF GLUCOSE IN AQUEOUS-SOLUTIONS [J].
HAZEN, KH ;
ARNOLD, MA ;
SMALL, GW .
APPLIED SPECTROSCOPY, 1994, 48 (04) :477-483
[7]  
Kawano S., 1995, J NEAR INFRARED SPEC, V3, P211, DOI DOI 10.1255/JNIRS.71
[8]   LOCALLY WEIGHTED REGRESSION IN DIFFUSE NEAR-INFRARED TRANSMITTANCE SPECTROSCOPY [J].
NAES, T ;
ISAKSSON, T .
APPLIED SPECTROSCOPY, 1992, 46 (01) :34-43
[9]  
NAES T, 1990, ANAL CHEM, V62, P668
[10]   Influence and correction of peak shift and band broadening observed by rank analysis on vibrational bands from variable-temperature measurements [J].
Nodland, E ;
Libnau, FO ;
Kvalheim, OM ;
Luinge, HJ ;
Klaeboe, P .