Fast accurate iterative reconstruction for low-statistics positron volume imaging

被引:140
作者
Reader, AJ [1 ]
Erlandsson, K [1 ]
Flower, MA [1 ]
Ott, RJ [1 ]
机构
[1] Royal Marsden NHS Trust, Joint Dept Phys, Canc Res Inst, Sutton SM2 5PT, Surrey, England
关键词
D O I
10.1088/0031-9155/43/4/012
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A fast accurate iterative reconstruction (FAIR) method suitable for low-statistics positron volume imaging has been developed. The method, based on the expectation maximization-maximum likelihood (EM-ML) technique, operates on list-mode data rather than histogrammed projection data and can, in just one pass through the data, generate images with the same characteristics as several ML iterations. Use of list-mode data preserves maximum sampling accuracy and implicitly ignores lines of response (LORs) in which no counts were recorded. The method is particularly suited to systems where sampling accuracy can be lost by histogramming events into coarse LOR bins, and also to sparse data situations such as fast whole-body and dynamic imaging where sampling accuracy may be compromised by storage requirements and where reconstruction time can be wasted by including LORs with no counts. The technique can be accelerated by operating on subsets of list-mode data which also allows scope for simultaneous data acquisition and iterative reconstruction. The method is compared with a standard implementation of the EM-ML technique and is shown to offer improved resolution, contrast and noise properties as a direct result of using improved spatial sampling, limited only by hardware specifications.
引用
收藏
页码:835 / 846
页数:12
相关论文
共 9 条
[1]   List-mode likelihood [J].
Barrett, HH ;
White, T ;
Parra, LC .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1997, 14 (11) :2914-2923
[2]   A row-action alternative to the EM algorithm for maximizing likelihoods in emission tomography [J].
Browne, J ;
DePierro, AR .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1996, 15 (05) :687-699
[3]   ACCELERATED IMAGE-RECONSTRUCTION USING ORDERED SUBSETS OF PROJECTION DATA [J].
HUDSON, HM ;
LARKIN, RS .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (04) :601-609
[4]   ACCELERATED ITERATIVE RECONSTRUCTION FOR POSITRON EMISSION TOMOGRAPHY BASED ON THE EM ALGORITHM FOR MAXIMUM-LIKELIHOOD-ESTIMATION [J].
LEWITT, RM ;
MUEHLLEHNER, G .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1986, 5 (01) :16-22
[5]   THE PERFORMANCE OF A MULTIWIRE PROPORTIONAL CHAMBER POSITRON CAMERA FOR CLINICAL USE [J].
MARSDEN, PK ;
OTT, RJ ;
BATEMAN, JE ;
CHERRY, SR ;
FLOWER, MA ;
WEBB, S .
PHYSICS IN MEDICINE AND BIOLOGY, 1989, 34 (08) :1043-1062
[6]  
PARRA LC, 1998, IN PRESS IEEE T MED
[7]   Iterative reconstruction of PET images using a high-overrelaxation single-projection algorithm [J].
Schmidlin, P ;
Bellemann, ME ;
Brix, G .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (03) :569-582
[8]  
Shepp L A, 1982, IEEE Trans Med Imaging, V1, P113, DOI 10.1109/TMI.1982.4307558