Estimation of the pulmonary capillary wedge pressure from transesophageal pulsed Doppler echocardiography of pulmonary venous flow: Influence of the respiratory cycle during mechanical ventilation

被引:11
作者
Girard, F
Couture, P
Boudreault, D
Normandin, L
Denault, A
Girard, D
机构
[1] Univ Montreal, Dept Anesthesie Reanimat, Quebec City, PQ, Canada
[2] Univ Montreal, Dept Chirurg Cardiaque, Quebec City, PQ, Canada
关键词
transesophageal echocardiography; Doppler; pulmonary venous flow; cardiac surgery; pulmonary capillary wedge pressure;
D O I
10.1016/S1053-0770(98)90049-0
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective:Pulsed Doppler measurement of pulmonary venous flow (PVF) in the left superior pulmonary vein has been suggested as a noninvasive method to evaluate pulmonary capillary wedge pressure (PCWP). In previous studies, PVF was measured at end-expiration, and it is unknown to what extent PVF is affected by the respiratory cycle. It is hypothesized that phasic variations of PVF during mechanical ventilation may be used to estimate PCWP. Design: Prospective clinical study. Setting: Tertiary care university hospital. Participants: Thirty patients undergoing elective cardiac surgery. Interventions: At multiple intervals during the surgery, the PVF was measured with transesophageal pulsed Doppler echocardiography, and measurements of PCWP and airway pressure were simultaneously obtained. Measurements and Results: Components of PVF evaluated were the systolic (X), diastolic (Y), and atrial (Z) waves with their velocity-time integrals (VTI). The systolic fraction (SF = VTI X/[VTI X + VTI Y]) and respiratory variations of each component of PVF were determined and compared with PCWP. There was a greater respiratory variation of the X wave (X expiratory-X inspiratory/X expiratory) in patients with PCWP <18 mmHg than in patients with PCWP greater than or equal to 18 mmHg (0.19 +/- 0.19 v 0.14 +/- 0.13, respectively, p < 0.01). PVF components measured at end-expiration that related best with PCWP were the X/Y peak velocities (r = -0.53), VTI X/VTI Y ratio (r = -0.42), and the SF (r = -0.49). When measured during end-inspiration. the relation of the X/Y ratio, VTI X/VTI Y,and SF with the PCWP were r = -0.54, r = -0.41, and r = -0.50, respectively. Conclusions: It has been documented that PVF velocity is influenced by the respiratory cycle during mechanical ventilation in patients undergoing cardiac surgery, and the magnitude of this variation is influenced by PCWP. However, it is not actually possible to predict PCWP accurately using these findings. Further studies are needed in which preload is varied acutely to confirm the usefulness of the results. Copyright (C) 1998 by W.B. Saunders Company.
引用
收藏
页码:16 / 21
页数:6
相关论文
共 20 条
[1]  
Basnight M A, 1991, J Am Soc Echocardiogr, V4, P547
[2]   EFFECT OF LUNG-INFLATION ON LUNG BLOOD-VOLUME AND PULMONARY VENOUS FLOW [J].
BROWER, R ;
WISE, RA ;
HASSAPOYANNES, C ;
BROMBERGERBARNEA, B ;
PERMUTT, S .
JOURNAL OF APPLIED PHYSIOLOGY, 1985, 58 (03) :954-963
[3]   EFFECT OF INTRA-THORACIC PRESSURE ON LEFT-VENTRICULAR PERFORMANCE [J].
BUDA, AJ ;
PINSKY, MR ;
INGELS, NB ;
DAUGHTERS, GT ;
STINSON, EB ;
ALDERMAN, EL .
NEW ENGLAND JOURNAL OF MEDICINE, 1979, 301 (09) :453-459
[4]   RELATION BETWEEN PULMONARY VENOUS FLOW AND PULMONARY WEDGE PRESSURE - INFLUENCE OF CARDIAC-OUTPUT [J].
CASTELLO, R ;
VAUGHN, M ;
DRESSLER, FA ;
MCBRIDE, LR ;
WILLMAN, VL ;
KAISER, GC ;
SCHWEISS, JF ;
OFILI, EO ;
LABOVITZ, AJ .
AMERICAN HEART JOURNAL, 1995, 130 (01) :127-134
[5]   HEMODYNAMIC EFFECTS OF PULMONARY VENTILATION [J].
CONWAY, CM .
BRITISH JOURNAL OF ANAESTHESIA, 1975, 47 (07) :761-766
[6]   HOSPITAL TREATMENT OF CONGESTIVE HEART-FAILURE - MANAGEMENT ACCORDING TO HEMODYNAMIC PROFILE [J].
FORRESTER, JS ;
WATERS, DD .
AMERICAN JOURNAL OF MEDICINE, 1978, 65 (01) :173-180
[7]   MITRAL AND PULMONARY VENOUS FLOW UNDER INFLUENCE OF POSITIVE END-EXPIRATORY PRESSURE VENTILATION ANALYZED BY TRANSESOPHAGEAL PULSED DOPPLER ECHOCARDIOGRAPHY [J].
HOFFMANN, R ;
LAMBERTZ, H ;
JUTTEN, H ;
FLACHSKAMPF, FA ;
HANRATH, P .
AMERICAN JOURNAL OF CARDIOLOGY, 1991, 68 (06) :697-701
[8]   SIMULTANEOUS MEASUREMENT OF PULMONARY VENOUS FLOW BY INTRAVASCULAR CATHETER DOPPLER VELOCIMETRY AND TRANSESOPHAGEAL DOPPLER-ECHOCARDIOGRAPHY - RELATION TO LEFT ATRIAL PRESSURE AND LEFT ATRIAL AND LEFT-VENTRICULAR FUNCTION [J].
HOFMANN, T ;
KECK, A ;
VANINGEN, G ;
SIMIC, O ;
OSTERMEYER, J ;
MEINERTZ, T .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 26 (01) :239-249
[9]   INFLUENCE OF LOADING CONDITIONS AND CONTRACTILE STATE ON PULMONARY VENOUS FLOW - VALIDATION OF DOPPLER VELOCIMETRY [J].
HOIT, BD ;
SHAO, YF ;
GABEL, M ;
WALSH, RA .
CIRCULATION, 1992, 86 (02) :651-659
[10]  
Klein A L, 1991, J Am Soc Echocardiogr, V4, P379