Stabilization of regenerating-mode operation in sensorless induction motor drives by full-order flux observer design

被引:92
作者
Hinkkanen, M [1 ]
Luomi, J [1 ]
机构
[1] Helsinki Univ Technol, Power Elect Lab, FIN-02015 Espoo, Finland
关键词
full-order flux observer; induction motor drives; speed sensorless; stability analysis;
D O I
10.1109/TIE.2004.837902
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper deals with the full-order flux observer design for speed-sensorless induction motor drives. An unstable region encountered in the regenerating mode at low speeds is well known. To remedy the problem, a modified speed-adaptation law is proposed. Instead of using only the current estimation error perpendicular to the estimated flux, the parallel component is also exploited in the regenerating mode. Using current estimation error loci in steady state, a linearized model, simulations, and experiments, it is shown that the observer using the proposed speed-adaptation law does not have the unstable region. It is also shown that the effect of erroneous parameter estimates on the accuracy of the observer is comparatively small.
引用
收藏
页码:1318 / 1328
页数:11
相关论文
共 17 条
[1]   Analysis and design of current regulators using complex vectors [J].
Briz, F ;
Degner, MW ;
Lorenz, RD .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2000, 36 (03) :817-825
[2]   Instability phenomena and remedies in sensorless indirect field oriented control [J].
Harnefors, L .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2000, 15 (04) :733-743
[4]   Parameter sensitivity of full-order flux observers for induction motors [J].
Hinkkanen, M ;
Luomi, J .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2003, 39 (04) :1127-1135
[5]   Speed-sensorless vector torque control of induction machines using a two-time-scale approach [J].
Hofmann, H ;
Sanders, SR .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1998, 34 (01) :169-177
[6]   A PHYSICALLY INSIGHTFUL APPROACH TO THE DESIGN AND ACCURACY ASSESSMENT OF FLUX OBSERVERS FOR FIELD-ORIENTED INDUCTION MACHINE DRIVES [J].
JANSEN, PL ;
LORENZ, RD .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1994, 30 (01) :101-110
[7]   Sensorless vector control scheme for induction motors based on a stator flux estimator with quadrant error compensation rule [J].
Kim, J ;
Nam, K ;
Chung, JH ;
Sunwoo, H .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2003, 39 (02) :492-503
[8]   Regenerating-mode low-speed operation of sensorless induction motor drive with adaptive observer [J].
Kubota, H ;
Sato, I ;
Tamura, Y ;
Matsuse, K ;
Ohta, H ;
Hori, Y .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2002, 38 (04) :1081-1086
[9]   DSP-BASED SPEED ADAPTIVE FLUX OBSERVER OF INDUCTION-MOTOR [J].
KUBOTA, H ;
MATSUSE, K ;
NAKANO, T .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1993, 29 (02) :344-348
[10]   Speed-sensorless direct torque control of induction motors using an adaptive flux observer [J].
Maes, J ;
Melkebeek, JA .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2000, 36 (03) :778-785