Carbon nanotube-enhanced electrochemical DNA biosensor for DNA hybridization detection

被引:327
作者
Cai, H [1 ]
Cao, XN [1 ]
Jiang, Y [1 ]
He, PG [1 ]
Fang, YZ [1 ]
机构
[1] E China Normal Univ, Dept Chem, Shanghai 200062, Peoples R China
基金
中国国家自然科学基金;
关键词
functionalized multi-walled carbon nanotubes DNA immobilization; hybridization; electrochemical DNA biosensor; daunomycin;
D O I
10.1007/s00216-002-1652-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel and sensitive electrochemical DNA biosensor based on multi-walled carbon nanotubes functionalized with a carboxylic acid group (MWNTs-COOH) for covalent DNA immobilization and enhanced hybridization detection is described. The MWNTs-COOH-modified glassy carbon electrode (GCE) was fabricated and oligonucleotides with the 5'-amino group were covalently bonded to the carboxyl group of carbon nanotubes. The hybridization reaction on the electrode was monitored by differential pulse voltammetry (DPV) analysis using an electroactive intercalator daunomycin as an indicator. Compared with previous DNA sensors with oligonucleotides directly incorporated on carbon electrodes, this carbon nanotube-based assay with its large surface area and good charge-transport characteristics dramatically increased DNA attachment quantity and complementary DNA detection sensitivity. This is the first application of carbon nanotubes to the fabrication of an electrochemical DNA biosensor with a favorable performance for the rapid detection of specific hybridization.
引用
收藏
页码:287 / 293
页数:7
相关论文
共 46 条
[1]   Fiber-optic evanescent wave biosensor for the detection of oligonucleotides [J].
Abel, AP ;
Weller, MG ;
Duveneck, GL ;
Ehrat, M ;
Widmer, HM .
ANALYTICAL CHEMISTRY, 1996, 68 (17) :2905-2912
[2]  
[Anonymous], [No title captured]
[3]  
Balavoine F, 1999, ANGEW CHEM INT EDIT, V38, P1912, DOI 10.1002/(SICI)1521-3773(19990712)38:13/14<1912::AID-ANIE1912>3.0.CO
[4]  
2-2
[5]   Carbon nanotube electrode for oxidation of dopamine [J].
Britto, PJ ;
Santhanam, KSV ;
Ajayan, PM .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1996, 41 (01) :121-125
[6]  
Britto PJ, 1999, ADV MATER, V11, P154, DOI 10.1002/(SICI)1521-4095(199902)11:2<154::AID-ADMA154>3.0.CO
[7]  
2-B
[8]   Colloid Au-enhanced DNA immobilization for the electrochemical detection of sequence-specific DNA [J].
Cai, H ;
Xu, C ;
He, PG ;
Fang, YZ .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2001, 510 (1-2) :78-85
[9]   Evaluation of different carbon electrodes for adsorptive stripping analysis of nucleic acids [J].
Cai, XH ;
Rivas, G ;
Farias, PAM ;
Shiraishi, H ;
Wang, J ;
Palecek, E .
ELECTROANALYSIS, 1996, 8 (8-9) :753-758
[10]   DETECTION OF SPECIFIC DNA-SEQUENCES BY FLUORESCENCE AMPLIFICATION - A COLOR COMPLEMENTATION ASSAY [J].
CHEHAB, FF ;
KAN, YW .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1989, 86 (23) :9178-9182