Robotic mitral valve repair: Experience with the da Vinci system

被引:142
作者
Nifong, LW
Chu, VF
Bailey, BM
Maziarz, DM
Sorrell, VL
Holbert, D
Chitwood, WR
机构
[1] E Carolina Univ, Dept Surg, Brody Sch Med, Greenville, NC 27858 USA
[2] E Carolina Univ, Ctr Minimally Invas & Robot Surg, Brody Sch Med, Greenville, NC 27858 USA
[3] E Carolina Univ, Med Ctr, Brody Sch Med, Greenville, NC 27858 USA
[4] E Carolina Univ, Ctr Stat, Brody Sch Med, Greenville, NC 27858 USA
关键词
D O I
10.1016/S0003-4975(02)04554-X
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. As part of a Food and Drug Administration trial, mitral repairs were performed in 38 patients using the robotic da Vinci surgical system (Intuitive Surgical, Inc, Mountain View, CA). Prospectively, we evaluated safety and efficacy in performing both simple and complex mitral repairs. Methods. Eligible patients had nonischemic moderate to severe mitral insufficiency. Operative techniques included peripheral cardiopulmonary perfusion, a 4- to 5-cm mini-thoracotomy, transthoracic aortic occlusion, and antegrade blood cardioplegia. Transesophageal echocardiograrns were done intraoperatively with three-dimensional reconstructions. Successful repairs were defined as mild or less residual regurgitation. Results. Enhanced three-dimensional visualization of mitral leaflets and the subvalvar apparatus allowed safe, dexterous intracardiac tissue manipulation. All patients had successful valve repairs including quadrangular resections, sliding plasties, and edge-to-edge approximations, as well as both chordal transfers and replacements. There were no operative deaths, strokes, or device- related complications. One patient required valve replacement for hemolysis and 1 was reexplored for bleeding. There were no incisional conversions. Both robotic repair and total operating times decreased significantly from 1.9 +/- 0.1 and 5.1 +/- 0.1 hours (mean standard error of the mean) for the first 19 patients to 1.5 +/- 0.1 (p = 0.002) and 4.4 +/- 0.1 hours (p = 0.04) for the last 19 operations, respectively. Total hospital length of stay for patients was 3.8 +/- 0.6 days. Of all patients, 31 (82%) had a 4-day or less length of stay. Seven patients (18%) had stays between 5 and 9 days (6.4 +/- 1.0). Conclusions. This study shows that the da Vinci surgical system (Intuitive Surgical, Inc) has few limitations in performing complex valve repairs. Articulated wrist-like instruments and three-dimensional visualization enabled precise tissue telernanipulation. Future robotic design advances and adjunctive suture technologies may promote continuing evolution of robotic cardiac operations. (C) 2003 by The Society of Thoracic Surgeons.
引用
收藏
页码:438 / 442
页数:5
相关论文
共 20 条
  • [1] First computer assisted open heart operation
    Carpentier, A
    Loulmet, D
    Aupecle, B
    Kieffer, JP
    Tournay, D
    Guibourt, P
    Fiemeyer, A
    Meleard, D
    Richomme, P
    Cardon, C
    [J]. COMPTES RENDUS DE L ACADEMIE DES SCIENCES SERIE III-SCIENCES DE LA VIE-LIFE SCIENCES, 1998, 321 (05): : 437 - 442
  • [2] Carpentier A, 1996, CR ACAD SCI III-VIE, V319, P219
  • [3] Robotic mitral valve repair: Trapezoidal resection and prosthetic annuloplasty with the da Vinci surgical system
    Chitwood, WR
    Nifong, LW
    Elbeery, JE
    Chapman, WH
    Albrecht, R
    Kim, V
    Young, JA
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2000, 120 (06) : 1171 - 1172
  • [4] Video-assisted minimally invasive mitral valve surgery: The ''micro-mitral'' operation
    Chitwood, WR
    Elbeery, JR
    Chapman, WHH
    Moran, JM
    Lust, RL
    Wooden, WA
    Deaton, DH
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1997, 113 (02) : 413 - 414
  • [5] Minimally invasive mitral valve repair using transthoracic aortic occlusion
    Chitwood, WR
    Elbeery, JR
    Moran, JF
    Balch, DC
    Chapman, WHH
    Deaton, DH
    Lust, RM
    Wooden, WA
    [J]. ANNALS OF THORACIC SURGERY, 1997, 63 (05) : 1477 - 1479
  • [6] Robotic surgical training in an academic institution
    Chitwood, WR
    Nifong, W
    Chapman, WHH
    Felger, JE
    Bailey, BM
    Ballint, T
    Mendleson, KG
    Kim, VB
    Young, JA
    Albrecht, RA
    [J]. ANNALS OF SURGERY, 2001, 234 (04) : 475 - 484
  • [7] CHITWOOD WR, 2000, OPERATIVE TECHNIQUES, P190
  • [8] Minimally invasive cardiac valve surgery improves patient satisfaction while reducing costs of cardiac valve replacement and repair
    Cohn, LH
    Adams, DH
    Couper, GS
    Bichell, DP
    Rosborough, DM
    Sears, SP
    Aranki, SF
    [J]. ANNALS OF SURGERY, 1997, 226 (04) : 421 - 426
  • [9] Minimally invasive valve operations
    Cosgrove, DM
    Sabik, JF
    Navia, JL
    [J]. ANNALS OF THORACIC SURGERY, 1998, 65 (06) : 1535 - 1538
  • [10] Functional anatomy of mitral regurgitation - Accuracy and outcome implications of transesophageal echocardiography
    Enriquez-Sarano, R
    Freeman, WK
    Tribouilloy, CM
    Orszulak, TA
    Khandheria, BK
    Seward, JB
    Bailey, KR
    Tajik, AJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 34 (04) : 1129 - 1136