Charge derivatization by 4-sulfophenyl isothiocyanate enhances peptide sequencing by post-source decay matrix-assisted laser desorption/ionization time-of-flight mass spectrometry

被引:59
作者
Marekov, LN [1 ]
Steinert, PM [1 ]
机构
[1] NIAMSD, Skin Biol Lab, NIH, Bethesda, MD 20892 USA
来源
JOURNAL OF MASS SPECTROMETRY | 2003年 / 38卷 / 04期
关键词
peptides; charge derivatization; post-source decay; matrix-assisted laser desorption/ionization time-of-flight mass spectrometry; sequencing;
D O I
10.1002/jms.448
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
High-sensitivity, rapid identification of proteins in proteomic studies normally uses a combination of one- or two-dimensional electrophoresis together with mass spectrometry. The simplicity and sensitivity of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) have increased its application in recent years. The most common method of 'peptide fingerprinting' often may not provide robust identification. Normally additional sequence information by post-source decay (PSD) MALDI-TOFMS provides additional constraints for database searches to achieve highly confident results. Here we describe a derivatization procedure to facilitate the acquisition of such sequence information. Peptide digests from a skin-expressed protein were modified with 4-sulfophenyl isothiocyanate. The resulting peptides carry a fixed negative charge at the N-terminal end and the resulting PSD spectrum is dominated by C-terminal y-type ions. The sequence information in most cases can be obtained manually or with simple programming tools. Methods of optimizing the procedure and increasing the sensitivity are discussed. Copyright (C) 2003 John Wiley Sons, Ltd.
引用
收藏
页码:373 / 377
页数:5
相关论文
共 37 条
[1]  
Adamczyk M, 1999, RAPID COMMUN MASS SP, V13, P1413, DOI 10.1002/(SICI)1097-0231(19990730)13:14<1413::AID-RCM657>3.0.CO
[2]  
2-4
[3]  
Ambihapathy K, 1997, J MASS SPECTROM, V32, P209, DOI 10.1002/(SICI)1096-9888(199702)32:2<209::AID-JMS466>3.3.CO
[4]  
2-3
[5]   SEQUENCING OF PEPTIDES BY TANDEM MASS-SPECTROMETRY AND HIGH-ENERGY COLLISION-INDUCED DISSOCIATION [J].
BIEMANN, K .
METHODS IN ENZYMOLOGY, 1990, 193 :455-479
[6]  
Brancia FL, 2000, RAPID COMMUN MASS SP, V14, P2070, DOI 10.1002/1097-0231(20001115)14:21<2070::AID-RCM133>3.0.CO
[7]  
2-G
[8]  
BRAUNITZER G, 1971, H-S Z PHYSIOL CHEM, V352, P1730
[9]   Peptide and protein identification by matrix-assisted laser desorption ionization (MALDI) and MALDI-post-source decay time-of-flight mass spectrometry [J].
Chaurand, P ;
Luetzenkirchen, F ;
Spengler, B .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1999, 10 (02) :91-103
[10]   Role of accurate mass measurement (±10 ppm) in protein identification strategies employing MS or MS MS and database searching [J].
Clauser, KR ;
Baker, P ;
Burlingame, AL .
ANALYTICAL CHEMISTRY, 1999, 71 (14) :2871-2882