Determination of morphine in water immiscible process streams using sequential injection analysis coupled with acidic permanganate chemiluminescence detection

被引:43
作者
Barnett, NW [1 ]
Lenehan, CE
Lewis, SW
Tucker, DJ
Essery, KM
机构
[1] Deakin Univ, Sch Biol & Chem Sci, Geelong, Vic 3217, Australia
[2] Glaxo Wellcome Australia Ltd, Port Fairy, Vic 3284, Australia
关键词
sequential injection analysis; acidic permanganate chemiluminescence; morphine; non-aqueous process streams;
D O I
10.1039/a708425k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A procedure for the determination of morphine in non-aqueous, water immiscible, process streams by sequential injection analysis is presented. Detection was based upon the chemiluminescence reaction of morphine with acidic potassium permanganate in the presence of sodium polyphosphate, which was carried out in a heterogeneous reaction environment, The calibration graph (range 0.005-0.12% m/v) was non-linear, with a polynomial equation of best fit of y = -384x(2) + 139x -4.84 (R-2 = 0.9990), where y represents the singal (mV) and x represents the morphine concentration (% m/v), and was analytically useful over the range 0.01-0.1% m/v. Precision las measured by relative standard deviation) was 6.0% for 10 replicate analyses of a non-aqueous morphine standard (0.075% m/v), Methyltriphenylphosphonium permanganate was investigated as an alternative chemiluminescent reagent and was found to deliver a similar analytical performance to potassium permanganate, Sequential injection analysis coupled with chemiluminescence detection afforded results for the determination of morphine in non-aqueous process samples which mere in good agreement with those obtained using a standard liquid chromatographic method, with an analytical throughput in excess of 120 h(-1).
引用
收藏
页码:601 / 605
页数:5
相关论文
共 29 条
  • [1] DETERMINATION OF MORPHINE BY FLOW-INJECTION ANALYSIS WITH CHEMILUMINESCENCE DETECTION
    ABBOTT, RW
    TOWNSHEND, A
    GILL, R
    [J]. ANALYST, 1986, 111 (06) : 635 - 640
  • [2] FLOW-INJECTION TECHNIQUES FOR WATER MONITORING
    ANDREW, KN
    BLUNDELL, NJ
    PRICE, D
    WORSFOLD, PJ
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (18) : A916 - A922
  • [3] DETERMINATION OF MORPHINE IN-PROCESS STREAMS USING FLOW-INJECTION ANALYSIS WITH CHEMILUMINESCENCE DETECTION
    BARNETT, NW
    ROLFE, DG
    BOWSER, TA
    PATON, TW
    [J]. ANALYTICA CHIMICA ACTA, 1993, 282 (03) : 551 - 557
  • [4] Barnett NW, 1996, FRESEN J ANAL CHEM, V355, P591
  • [5] BARNETT NW, 1998, IN PRESS ANAL CHIM A
  • [6] RAPID-DETERMINATION OF TOTAL BIOMASS FROM A YEAST FERMENTATION USING SEQUENTIAL INJECTION
    BAXTER, PJ
    CHRISTIAN, GD
    RUZICKA, J
    [J]. ANALYST, 1994, 119 (08) : 1807 - 1812
  • [7] CONFIGURATIONS OF A FLOW-INJECTION SYSTEM FOR PERFUSION STUDIES OF ADHERENT CELLS
    BAXTER, PJ
    HALLGREN, L
    POLLEMA, CH
    TRNKA, M
    RUZICKA, J
    [J]. ANALYTICAL CHEMISTRY, 1995, 67 (08) : 1486 - 1490
  • [8] Bowie AR, 1996, J BIOLUM CHEMILUM, V11, P61, DOI 10.1002/(SICI)1099-1271(199603)11:2<61::AID-BIO406>3.0.CO
  • [9] 2-O
  • [10] CALATAYUD JM, 1996, FLOW INJECTION ANAL, P51