Chiral electrochromatography with a 'moulded' rigid monolithic capillary column

被引:117
作者
Peters, EC [1 ]
Lewandowski, K [1 ]
Petro, M [1 ]
Svec, F [1 ]
Frechet, JMJ [1 ]
机构
[1] Univ Calif Berkeley, Dept Chem, Berkeley, CA 94720 USA
来源
ANALYTICAL COMMUNICATIONS | 1998年 / 35卷 / 03期
关键词
D O I
10.1039/a708968f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Several monolithic chiral stationary phases for reversed-phase electrochromatography have been prepared within the confines of untreated fused silica capillaries by the direct copolymerization of the chiral monomer 2-hydroxyethyl methacrylate (N-L-valine-3,5-dimethylanilide) carbamate with ethylene dimethacrylate, 2-acrylamido-2-methyl-1-propanesulfonic acid and butyl or glycidyl methacrylate in the presence of a porogenic solvent, The hydrophilicity of the stationary phase, which may be enhanced further by the hydrolysis of the epoxide functionalities of the glycidyl methacrylate moieties within the monolith, was found to have a pronounced effect on the enantioseparation. Using the most hydrophilic monolithic capillary column and optimized elution conditions, a separation of N-(3,5-dinitrobenzoyl)leucine diallylamide enantiomers with an efficiency of 61 000 plates m(-1) and a resolution of 2.0 was achieved.
引用
收藏
页码:83 / 86
页数:4
相关论文
共 22 条
[1]  
COLON JA, 1997, ANAL CHEM, V69, pA461
[2]   Electrochromatography [J].
Crego, AL ;
Gonzalez, A ;
Marina, ML .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1996, 26 (04) :261-304
[3]  
Dittmann MM, 1995, LC GC-MAG SEP SCI, V13, P800
[4]  
Jakubetz H, 1997, J MICROCOLUMN SEP, V9, P421, DOI 10.1002/(SICI)1520-667X(1997)9:5<421::AID-MCS8>3.0.CO
[5]  
2-3
[6]   Capillary electrochromatography: Operating characteristics and enantiomeric separations [J].
Lelievre, F ;
Yan, C ;
Zare, RN ;
Gareil, P .
JOURNAL OF CHROMATOGRAPHY A, 1996, 723 (01) :145-156
[7]  
LEWANDOWSKI K, UNPUB ANAL CHEM
[8]   PACKED-CAPILLARY ELECTROCHROMATOGRAPHIC SEPARATION OF THE ENANTIOMERS OF NEUTRAL AND ANIONIC COMPOUNDS USING BETA-CYCLODEXTRIN AS A CHIRAL SELECTOR - EFFECT OF OPERATING PARAMETERS AND COMPARISON WITH FREE-SOLUTION CAPILLARY ELECTROPHORESIS [J].
LI, S ;
LLOYD, DK .
JOURNAL OF CHROMATOGRAPHY A, 1994, 666 (1-2) :321-335
[9]   DIRECT CHIRAL SEPARATIONS BY CAPILLARY ELECTROPHORESIS USING CAPILLARIES PACKED WITH AN ALPHA(1)-ACID GLYCOPROTEIN CHIRAL STATIONARY-PHASE [J].
LI, S ;
LLOYD, DK .
ANALYTICAL CHEMISTRY, 1993, 65 (24) :3684-3690
[10]   Capillary electrochromatographic separation of amino acid enantiomers with molecularly imprinted polymers as chiral recognition agents [J].
Lin, JM ;
Nakagama, T ;
Wu, XZ ;
Uchiyama, K ;
Hobo, T .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 357 (01) :130-132