Genetically engineered biologically based hemostatic bioassay

被引:3
作者
Tang, LL
Christini, DJ
Edelberg, JM
机构
[1] Cornell Univ, Weill Med Coll, Dept Med, New York, NY 10021 USA
[2] Cornell Univ, Weill Med Coll, Dept Physiol & Biophys, New York, NY 10021 USA
[3] Cornell Univ, Weill Med Coll, Dept Cellular & Dev Biol, New York, NY 10021 USA
关键词
tissue engineering; stem cell; coagulation; thrombin; biosensor;
D O I
10.1114/1.1537693
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Real-time direct measures of hemostatic parameters in vivo are required for optimizing the dynamic delivery of coagulation modifying pharmacotherapies. Typical sensors of physiologic functions in vivo, however, have only a restricted array of sensory inputs, and thug limited capacity to monitor thrombotic and hemostatic activity. To overcome this limitation we have developed a genetically engineered excitable cell line that can be potentially used for an implantable thrombin biosensor. Specifically, we have generated stem cell-derived cardiac myocyte aggregates overexpressing the human thrombin receptor, protease activated receptor-1 (PAR-1), which exploit the inherent electropotential input-output relationship of the cells to detect local changes in thrombin activity. In vitro, the signaling activity of PAR-1 cardiac myocytes was highly responsive to thrombin, inducing a sixfold increase in intracellular cAMP as compared with a twofold increase in control cells. In vivo, the engineered myocytes also detected alterations in local coagulation potential. Specifically, PAR-1 engineered cells implanted in vivo detected local increases in thrombin with a doubling in chronotropic activity compared with a 50% increase in control aggregates. Overall these studies demonstrate the potential of genetic engineering to expand the physiologic signals recognized by excitable cells, and may facilitate the translation of this approach for the real-time monitoring of hemostatic function in vivo. (C) 2003 Biomedical Engineering Society.
引用
收藏
页码:159 / 162
页数:4
相关论文
共 13 条
[1]   Practical real-time computing system for biomedical experiment interface [J].
Christini, DJ ;
Stein, KM ;
Markowitz, SM ;
Lerman, BB .
ANNALS OF BIOMEDICAL ENGINEERING, 1999, 27 (02) :180-186
[2]   Direct biologically based biosensing of dynamic physiological function [J].
Christini, DJ ;
Walden, J ;
Edelberg, JM .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2001, 280 (05) :H2006-H2010
[3]   How the protease thrombin talks to cells [J].
Coughlin, SR .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1999, 96 (20) :11023-11027
[4]   Preliminary study on the suitability of a pharmacological bio-assay based on cardiac myocytes cultured over microfabricated microelectrode arrays [J].
Denyer, MCT ;
Riehle, M ;
Britland, ST ;
Offenhauser, A .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1998, 36 (05) :638-644
[5]   Potentiation of beta-adrenergic signaling by adenoviral-mediated gene transfer in adult rabbit ventricular myocytes [J].
Drazner, MH ;
Peppel, KC ;
Dyer, S ;
Grant, AO ;
Koch, WJ ;
Lefkowitz, RJ .
JOURNAL OF CLINICAL INVESTIGATION, 1997, 99 (02) :288-296
[6]   Enhancement of murine cardiac chronotropy by the molecular transfer of the human β2 adrenergic receptor cDNA [J].
Edelberg, JM ;
Aird, WC ;
Rosenberg, RD .
JOURNAL OF CLINICAL INVESTIGATION, 1998, 101 (02) :337-343
[7]   Enhanced myocyte-based biosensing of the blood-borne signals regulating chronotropy [J].
Edelberg, JM ;
Jacobson, JT ;
Gidseg, DS ;
Tang, LL ;
Christini, DJ .
JOURNAL OF APPLIED PHYSIOLOGY, 2002, 92 (02) :581-585
[8]   A NEURON-SILICON JUNCTION - A RETZIUS CELL OF THE LEECH ON AN INSULATED-GATE FIELD-EFFECT TRANSISTOR [J].
FROMHERZ, P ;
OFFENHAUSSER, A ;
VETTER, T ;
WEIS, J .
SCIENCE, 1991, 252 (5010) :1290-1293
[9]   THE USE OF NEURONAL NETWORKS ON MULTIELECTRODE ARRAYS AS BIOSENSORS [J].
GROSS, GW ;
RHOADES, BK ;
AZZAZY, HME ;
WU, MC .
BIOSENSORS & BIOELECTRONICS, 1995, 10 (6-7) :553-567
[10]   Cardiomyocytes can be generated from marrow stromal cells in vitro [J].
Makino, S ;
Fukuda, K ;
Miyoshi, S ;
Konishi, F ;
Kodama, H ;
Pan, J ;
Sano, M ;
Takahashi, T ;
Hori, S ;
Abe, H ;
Hata, J ;
Umezawa, A ;
Ogawa, S .
JOURNAL OF CLINICAL INVESTIGATION, 1999, 103 (05) :697-705