Biosensor surface characterisation: confirming multilayer immobilisation, determining coverage of the biospecies and establishing detection limits

被引:16
作者
Berney, H [1 ]
Roseingrave, P
Alderman, J
Lane, W
Collins, JK
机构
[1] Natl Univ Ireland Univ Coll Cork, Natl Microelect Res Ctr, Cork, Ireland
[2] Natl Univ Ireland Univ Coll Cork, Microbiol Virol Dept, Cork, Ireland
关键词
biosensor characterization; detection limits; enzyme-linked immunosorbent assay;
D O I
10.1016/S0925-4005(97)00200-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Sensor behaviour is strongly influenced by the surface geometry and morphology of the immobilised biolayer. In a non-amplification system the detection limits are primarily determined by the number of active biomolecules immobilised on the transducer. It is critical to be able to measure this number in a reliable and reproducible manner for sensor characterisation. Without this information, sensor to sensor calibration cannot be performed and the system detection limits are not known. A routinely used immunological assay, enzyme-linked immunosorbent assay (ELISA), can be modified and used to detect the total number of molecules and the number of active molecules immobilised on a variety of surfaces. In conjunction with other surface techniques, scanning electron microscopy (SEM) and ellipsometry, the modified ELISA technique is a useful analysis tool for biosensor characterisation. (C) 1997 Elsevier Science S.A.
引用
收藏
页码:341 / 349
页数:9
相关论文
共 24 条
[1]   IRON TRANSPORT AND STORAGE PROTEINS [J].
AISEN, P ;
LISTOWSKY, I .
ANNUAL REVIEW OF BIOCHEMISTRY, 1980, 49 :357-393
[2]   STUDIES OF ONLINE VIABLE YEAST BIOMASS WITH A CAPACITANCE BIOMASS MONITOR [J].
AUSTIN, GD ;
WATSON, RWJ ;
DAMORE, T .
BIOTECHNOLOGY AND BIOENGINEERING, 1994, 43 (04) :337-341
[3]  
AZZAM A, 1986, ELLIPSOMETRY POLARIZ
[4]  
BATTAILLARD P, 1988, ANAL CHEM, V60, P2374
[5]  
Cooper J. C., 1992, AgBiotech News and Information, V4, P135
[6]   ELLIPSOMETRY AS A TOOL TO STUDY ADSORPTION BEHAVIOR OF SYNTHETIC AND BIOPOLYMERS AT AIR-WATER-INTERFACE [J].
DEFEIJTER, JA ;
BENJAMINS, J ;
VEER, FA .
BIOPOLYMERS, 1978, 17 (07) :1759-1772
[7]  
EDDOWES MJ, 1987, BIOSENSORS, V3, P1
[8]  
EIGLER FS, 1991, Patent No. 5077210
[9]  
GARDIES F, 1989, SENSOR ACTUAT B-CHEM, V17, P41
[10]   CAPACITIVE MEASUREMENTS IN ELECTROLYTE INSULATOR SEMICONDUCTOR (EIS) SYSTEMS MODIFIED BY BIOLOGICAL-MATERIALS [J].
GRATTAROLA, M ;
CAMBIASO, A ;
CENDERELLI, S ;
TEDESCO, M .
SENSORS AND ACTUATORS, 1989, 17 (3-4) :451-459