A new method to examine the intracranial arteries three-dimensional transcranial contrast duplex sonography

被引:7
作者
Delcker, A [1 ]
Turowski, B [1 ]
机构
[1] UNIV ESSEN GESAMTHSCH,NEURORADIOL ABT,ESSEN,GERMANY
来源
ULTRASCHALL IN DER MEDIZIN | 1997年 / 18卷 / 03期
关键词
transcranial duplex scanning; contrast media for TCD;
D O I
10.1055/s-2007-1000405
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A new data acquisition system for transcranial 3 D-ultrasonography was used. The present study examines the evaluation of intracranial cerebral arteries by 3 D-ultrasound and echo contrast agents in comparison to cerebral angiography, Methods: Ten patients, who underwent diagnostic cerebral angiography, were examined without knowledge of the angiographic results. Data acquisition through the transtemporal acoustic bone window was performed with a magnetic sensor system to track the spatial orientation of the ultrasound probe while scanning the volume of interest, We used a transcranial duplex system with power mode and stored a 3 D-data set before injection of transpulmonary stable contrast medium and afterwards. Results: Ipsilateral to the transducer anterior cerebral artery (ACA) in 90%, middle cerebral artery (MCA) in 90%, three or more branches of MCA in 60% and posterior cerebral artery (PCA) in 40% were analysed without injecting an echo contrast agent, After the contrast injection ACA, MCA, branches of MCA and PCA in 100% were visible. In 70% of cases the posterior and anterior communicating arteries were visualised only by means of a contrast agent. Conclusion: Application of a transpulmonary stable ultrasound contrast agent in combination with 3 D transcranial duplex ultrasonography significantly enhances the visualisation of intracranial arteries.
引用
收藏
页码:110 / 115
页数:6
相关论文
共 18 条
[1]  
Bartels E, 1994, J Neuroimaging, V4, P77
[2]  
BAUER A, 1996, CLIN RADIOL S1, V1, P19
[3]   Transcranial Doppler and color-coded duplex sonography: Established and new applications [J].
Baumgartner, RW ;
Baumgartner, IB .
ULTRASCHALL IN DER MEDIZIN, 1996, 17 (02) :50-54
[4]   CONTRAST-ENHANCED TRANSCRANIAL COLOR-CODED REAL-TIME SONOGRAPHY - RESULTS OF A PHASE-2 STUDY [J].
BOGDAHN, U ;
BECKER, G ;
SCHLIEF, R ;
REDDIG, J ;
HASSEL, W .
STROKE, 1993, 24 (05) :676-684
[5]   NONINVASIVE ASSESSMENT OF THE CIRCLE OF WILLIS USING TRANSCRANIAL PULSED DOPPLER ULTRASOUND WITH ANGIOGRAPHIC CORRELATION [J].
CHAUDHURI, R ;
PADAYACHEE, TS ;
LEWIS, RR ;
GOSLING, RG ;
COX, TCS .
CLINICAL RADIOLOGY, 1992, 46 (03) :193-197
[6]   QUANTIFICATION OF ATHEROSCLEROTIC PLAQUES IN CAROTID ARTERIES BY 3-DIMENSIONAL ULTRASOUND [J].
DELCKER, A ;
DIENER, HC .
BRITISH JOURNAL OF RADIOLOGY, 1994, 67 (799) :672-678
[7]   ULTRASOUND CONTRAST AGENTS - A REVIEW [J].
GOLDBERG, BB ;
LIU, JB ;
FORSBERG, F .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1994, 20 (04) :319-333
[8]   PRESENT STATUS OF TRANSCRANIAL COLOR-CODED SONOGRAPHY IN ADULTS [J].
KAPS, M ;
SEIDEL, G ;
DORNDORF, W .
ULTRASCHALL IN DER MEDIZIN, 1995, 16 (02) :50-59
[9]   Assessment of the posterior communicating artery by transcranial color-coded duplex sonography [J].
Klotzsch, C ;
Popescu, O ;
Berlit, P .
STROKE, 1996, 27 (03) :486-489
[10]   ESTIMATION OF EXTRACRANIAL BRAIN ARTERIES BY ULTRASOUND SONOGRAPHY [J].
KRUNES, U ;
BURGER, K .
ULTRASCHALL IN DER MEDIZIN, 1995, 16 (02) :73-78