Quantitative Immunochemical Fecal Occult Blood Testing for Colorectal Adenoma Detection: Evaluation in the Target Population of Screening and Comparison With Qualitative Tests

被引:81
作者
Haug, Ulrike [1 ]
Hundt, Sabrina [1 ]
Brenner, Hermann [1 ]
机构
[1] Univ Heidelberg, German Canc Res Ctr, Div Clin Epidemiol & Aging Res, D-69115 Heidelberg, Germany
关键词
TASK-FORCE; CANCER; COLONOSCOPY; POLYPS;
D O I
10.1038/ajg.2009.668
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
OBJECTIVES: Quantitative and qualitative immunochemical fecal occult blood tests (FOBTs) have been proposed for noninvasive colorectal cancer screening, but comparative evaluation is lacking. The aim of this study was to determine the diagnostic accuracy of two (quantitative) enzyme-linked immunosorbent assay (ELISA)-based immunochemical FOBTs for identifying colorectal adenomas in the target population of screening and to compare the results with six (qualitative) immunochromatographic FOBTs, previously evaluated in the same study participants using the same stool samples. METHODS: A total of 1,319 participants of screening colonoscopy at average risk for colorectal neoplasia (mean age 63 years; age range 31-86 years; 50% men) were recruited prospectively from January 2006 to December 2007 in collaboration with 20 gastroenterological practices in Germany. Fecal hemoglobin and hemoglobin-haptoglobin levels were measured using an automated ELISA (RIDASCREEN). Test performance characteristics at different cutoff values were derived by comparing the results of stool testing with the results of colonoscopy in a blinded manner. RESULTS: A total of 130 participants (10%) had an advanced adenoma. The area under the receiver-operating characteristic curve with regard to advanced adenomas was 0.68 (0.65-0.71) for hemoglobin and 0.64 (0.61-0.67) for hemoglobin-haptoglobin (P=0.034). At a specificity of similar to 95%, the sensitivity (95% confidence interval) for advanced adenomas was 33% (25-42%) for hemoglobin and 24% (17-32%) for hemoglobin-haptoglobin, respectively. The sensitivity for hemoglobin was very close to sensitivities of the six qualitative FOBTs at (strongly divergent) levels of specificity observed for the latter. CONCLUSIONS: ELISA-based measurement of hemoglobin was superior to hemoglobin-haptoglobin, but showed a similar sensitivity for advanced adenomas compared with (qualitative) immunochromatographic FOBTs at defined levels of specificity. Compared with the latter, its quantitative nature offers advantages in terms of transparency and flexibility regarding the positivity threshold (e. g., specificity can be oriented toward available colonoscopy resources or personal risk profiles) and in terms of a higher level of standardization regarding test analysis and interpretation.
引用
收藏
页码:682 / 690
页数:9
相关论文
共 19 条
[1]  
Altman DG, 2000, Statistics with confidence, V2nd
[2]   Colonoscopic withdrawal times and adenoma detection during screening colonoscopy [J].
Barclay, Robert L. ;
Vicari, Joseph J. ;
Doughty, Andrea S. ;
Johanson, John F. ;
Greenlaw, Roger L. .
NEW ENGLAND JOURNAL OF MEDICINE, 2006, 355 (24) :2533-2541
[3]   Diagnostic accuracy of faecal occult blood tests used in screening for colorectal cancer: a systematic review [J].
Burch, J. A. ;
Soares-Weiser, K. ;
St John, D. J. B. ;
Duffy, S. ;
Smith, S. ;
Kleijnen, J. ;
Westwood, M. .
JOURNAL OF MEDICAL SCREENING, 2007, 14 (03) :132-137
[4]   A randomised trial of the impact of new faecal haemoglobin test technologies on population participation in screening for colorectal cancer [J].
Cole, SR ;
Young, GP ;
Esterman, A ;
Cadd, B ;
Morcom, J .
JOURNAL OF MEDICAL SCREENING, 2003, 10 (03) :117-122
[5]   Statistics notes - Diagnostic tests 4: likelihood ratios [J].
Deeks, JJ ;
Altman, DG .
BRITISH MEDICAL JOURNAL, 2004, 329 (7458) :168-169
[6]   COMPARING THE AREAS UNDER 2 OR MORE CORRELATED RECEIVER OPERATING CHARACTERISTIC CURVES - A NONPARAMETRIC APPROACH [J].
DELONG, ER ;
DELONG, DM ;
CLARKEPEARSON, DI .
BIOMETRICS, 1988, 44 (03) :837-845
[7]   New stool tests for colorectal cancer screening: A systematic review focusing on performance characteristics and practicalness [J].
Haug, U ;
Brenner, H .
INTERNATIONAL JOURNAL OF CANCER, 2005, 117 (02) :169-176
[8]   PROSPECTIVE-STUDY OF THE FREQUENCY AND SIZE DISTRIBUTION OF POLYPS MISSED BY COLONOSCOPY [J].
HIXSON, LJ ;
FENNERTY, MB ;
SAMPLINER, RE ;
MCGEE, D ;
GAREWAL, H .
JNCI-JOURNAL OF THE NATIONAL CANCER INSTITUTE, 1990, 82 (22) :1769-1772
[9]   Comparative Evaluation of Immunochemical Fecal Occult Blood Tests for Colorectal Adenoma Detection [J].
Hundt, Sabrina ;
Haug, Ulrike ;
Brenner, Hermann .
ANNALS OF INTERNAL MEDICINE, 2009, 150 (03) :162-+
[10]   Blood markers for early detection of colorectal cancer: A systematic review [J].
Hundt, Sabrina ;
Haug, Ulrike ;
Brenner, Hermann .
CANCER EPIDEMIOLOGY BIOMARKERS & PREVENTION, 2007, 16 (10) :1935-1953