Intraoperative stimulus-evoked electromyographic monitoring for placement of iliosacral implants: An animal model

被引:14
作者
Moed, BR [1 ]
Anders, MJ [1 ]
Ahmad, BK [1 ]
Craig, JG [1 ]
Jacobson, GP [1 ]
机构
[1] Henry Ford Hosp K 12, Dept Orthopaed Surg, Div Orthopaed Traumatol, Detroit, MI 48202 USA
关键词
intraoperative nerve monitoring; iliosacral screws;
D O I
10.1097/00005131-199802000-00004
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: A canine model was designed to evaluate the feasibility of stimulus-evoked electromyographic (EMG) monitoring of the lumbosacral nerve roots during the insertion of iliosacral implants. Study Design/Methods: Four 2.5-millimeter Kirschner wires (K-wires) were percutaneously inserted under general anesthesia into the S1 body of each of five dog hemipelves using C-arm fluoroscopy image-intensifier control in an actual attempt to compromise the S1 canal and the S1 nerve root. A searching current of twenty milliamperes was initially applied to the K-wire with monitoring electrodes placed in the gastrocnemius muscle. Current thresholds required to evoke an EMG response were recorded for each K-wire. Actual K-wire location was determined by anatomical dissection. Results: Evaluation of these twenty wires revealed that current threshold was directly related to the proximity of the K-wire to the nerve root, with a correlation coefficient of 0.94 (p < 0.001). Conclusions: Stimulus-evoked EMG monitoring provided reliable data indicating the proximity of the iliosacral implants to the sacral nerve root. This method of intraoperative nerve monitoring could potentially decrease the risk of iatrogenic nerve root injury during pelvic ring surgery. Further study is warranted.
引用
收藏
页码:85 / 89
页数:5
相关论文
共 24 条
[1]
AHMAD BK, 1994, 5 ANN M AM SOC NEUR
[2]
BENECKE JE, 1987, LARYNGOSCOPE, V97, P697
[3]
ANATOMICAL AND HISTOLOGICAL STUDY OF SCIATIC-NERVE, RELATING TO PERIPHERAL-NERVE INJURIES IN DOG AND CAT [J].
BENNETT, D .
JOURNAL OF SMALL ANIMAL PRACTICE, 1976, 17 (06) :379-386
[4]
INTRAOPERATIVE EVOKED EMG MONITORING IN AN ANIMAL-MODEL - A NEW TECHNIQUE FOR EVALUATING PEDICLE SCREW PLACEMENT [J].
CALANCIE, B ;
LEBWOHL, N ;
MADSEN, P ;
KLOSE, KJ .
SPINE, 1992, 17 (10) :1229-1235
[5]
STIMULUS-EVOKED EMG MONITORING DURING TRANSPEDICULAR LUMBOSACRAL SPINE INSTRUMENTATION - INITIAL CLINICAL-RESULTS [J].
CALANCIE, B ;
MADSEN, P ;
LEBWOHL, N .
SPINE, 1994, 19 (24) :2780-2786
[6]
Outcome after fixation of unstable posterior pelvic ring injuries [J].
Cole, JD ;
Blum, DA ;
Ansel, LJ .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1996, (329) :160-179
[7]
GANTZ BJ, 1985, AM J OTOL, P58
[8]
INTRAOPERATIVE SOMATOSENSORY-EVOKED POTENTIAL MONITORING DURING ACUTE PELVIC FRACTURE SURGERY [J].
HELFET, DL ;
KOVAL, KJ ;
HISSA, EA ;
PATTERSON, S ;
DIPASQUALE, T ;
SANDERS, R .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1995, 9 (01) :28-34
[9]
KELLAM JP, 1995, FRACTURES PELVIS ACE, P150
[10]
TRIGGERED ELECTROMYOGRAPHIC THRESHOLD FOR ACCURACY OF PEDICLE SCREW PLACEMENT - AN ANIMAL-MODEL AND CLINICAL CORRELATION [J].
LENKE, LG ;
PADBERG, AM ;
RUSSO, MH ;
BRIDWELL, KH ;
GELB, DE .
SPINE, 1995, 20 (14) :1585-1591