Comparison and improvement of the determinations of actinide low activities using several α liquid scintillation spectrometers

被引:20
作者
Dacheux, N
Aupiais, J
Courson, O
Aubert, C
机构
[1] Univ Paris 11, Inst Nucl Phys, Grp Radiochim, F-91406 Orsay, France
[2] CEA, Serv Radioanalyses Chim Environm, Dept Analyse Surveillance Environm, F-91680 Bruyeres Le Chatel, France
关键词
D O I
10.1021/ac9914216
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We applied three procedures using two or liquid scintillation spectrometers (PERALS and TRI-CARB) and two scintillation cocktails (Alphaex and Ultima Gold LLT) for the determination of a-emitter low activities. For each procedure, the limit of detection, the resolution, the separation factor, and the Fischer coefficient were determined in order to perform U-232-U-234-U-238 isotopic measurements. The deconvolution usually performed is clean when the PERALS spectrometer is used. This is not possible for the TRI-CARB spectrometer using the Ultima Gold LLT scintillation cocktail. This problem was solved by combining the advantages of both techniques using the Alphaex scintillation cocktail in the TRI-CARB spectrometer, Under these conditions, the limit of detection was improved, the resolution decreased from 500-800 to 420-590 keV, and the separation factor increased from 0.9 to 1.1-1.2. This third procedure was applied with success for U-232-U-234-U-238 isotopic experiments.
引用
收藏
页码:3150 / 3157
页数:8
相关论文
共 34 条
[1]   Study of neptunium measurement by alpha liquid scintillation with rejection of β-γ emitters [J].
Aupiais, J ;
Dacheux, N ;
Thomas, AC ;
Matton, S .
ANALYTICA CHIMICA ACTA, 1999, 398 (2-3) :205-218
[2]   Alpha liquid scintillation measurement of plutonium in solution spiked by Pu-236 [J].
Aupiais, J .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1997, 218 (02) :201-207
[3]   Determination of 226Ra in mineral drinking waters by α liquid scintillation with rejection of β-γ emitters [J].
Aupiais, J ;
Fayolle, C ;
Gilbert, P ;
Dacheux, N .
ANALYTICAL CHEMISTRY, 1998, 70 (11) :2353-2359
[4]  
AUPIAIS J, IN PRESS RADIOCHIM A
[5]  
BOATNER LA, 1988, RADIOACTIVE WASTE FO, P556
[6]   Determination of plutonium radioactivity in Mururoa lagoon water [J].
Bourlat, Y ;
MilliesLacroix, JC ;
Nazard, R .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1995, 197 (02) :387-408
[7]  
BROWN DD, 1993, 39 ANN C BIOASS COL
[8]   DETERMINATION OF RADIUM IN NATURAL-WATERS BY ALPHA LIQUID SCINTILLATION [J].
BURNETT, WC ;
TAI, WC .
ANALYTICAL CHEMISTRY, 1992, 64 (15) :1691-1697
[9]   MEASUREMENT OF ACTINIDES IN ENVIRONMENTAL-SAMPLES BY PHOTON ELECTRON REJECTING ALPHA-LIQUID SCINTILLATION [J].
CADIEUX, JR ;
CLARK, S ;
FJELD, RA ;
REBOUL, S ;
SOWDER, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 353 (1-3) :534-538
[10]  
CADIEUX JR, 1990, 7 S RAD MEAS APPL U