Determination of chromium, molybdenum and vanadium dopants in bismuth tellurite optical crystals by multi-element graphite furnace atomic absorption spectrometry

被引:26
作者
Bencs, L
Szakács, O
Kántor, T
Varga, I
Bozsai, G
机构
[1] Hungarian Acad Sci, Res Inst Solid State Phys & Opt, H-1525 Budapest, Hungary
[2] Eotvos Lorand Univ Sci, Dept Gen & Inorgan Chem, H-1518 Budapest, Hungary
[3] Eotvos Lorand Univ Sci, Dept Inorgan & Analyt Chem, H-1518 Budapest, Hungary
[4] Natl Publ Hlth Ctr, Cent Lab, H-1450 Budapest, Hungary
基金
匈牙利科学研究基金会;
关键词
Cr; Mo; V; Bi(2)TeO(5); triammonium citrate chemical modifier; multi-injection; simultaneous determination;
D O I
10.1016/S0584-8547(00)00221-4
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The graphite furnace atomic absorption spectrometry (GFAAS) method were developed for the determination of chromium, molybdenum and vanadium dopants in a bismuth tellurite (Bi(2)TeO(5)) matrix, using a transversely heated graphite atomizer with longitudinal Zeeman background correction system. The bismuth tellurite matrix dissolved in HCl and modified by the addition of triammonium citrate (TAC) was found to be significantly more volatile than the analytes considered in the present analysis. Therefore, the matrix constituents could be removed by a selective vaporization during the pyrolysis step. By applying multiple sample dispension (5 x 20 mu l) and pre-vaporization of the matrix, the calibration could be performed using simple, matrix-free standard solutions. Under mini-flow conditions (50 cm(3) min(-1)), the simultaneous GFAAS determinations of Cr, Mo and V in Bi(2)TeO(5) crystals (single injection) are characterized by the limit of detection (LOD) values of 0.83, 3.9 and 4.7 mu g l(-1), respectively, whereas in the presence of the matrix, 1.14, 4.9 and 6.7 mu g l(-1) are found, respectively. The latter LOD data correspond to 0.18, 0.78 and 1.1 mu g g(-1) Cr, Mo and V, respectively, in the solid samples. The calibration curves of Cr, Mo and V are linear up to 40, 100 and 400 mu g l(-1), respectively. The characteristic masses are 7.5 pg Cr, 20 pg Mo and 58 pg V. For the multiple dosing and matrix pre-vaporization method, the LOD data of Cr, Mo and V an 0.16, 0.74 and 0.9 mu g l(-1) respectively, which correspond to 0.026, 0.12 and 0.14 mu g g(-1) Cr, Mo and V, respectively, in the solid samples. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:883 / 891
页数:9
相关论文
共 25 条
[1]   Determination of erbium and neodymium dopants in bismuth tellurite optical crystals by graphite furnace atomic spectrometry techniques [J].
Bencs, L ;
Szakács, O ;
Kántor, T .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1999, 54 (08) :1193-1206
[2]   Investigations on the determination of chromium dopant in bismuth tellurite single crystals by graphite furnace atomic absorption spectrometry [J].
Bencs, LF ;
Szakacs, O .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1997, 52 (9-10) :1483-1496
[3]   SOME OBSERVATIONS ON THE MECHANISMS FOR STABILIZATION OF CHROMIUM IN GRAPHITE FURNACE-ATOMIC ABSORPTION SPECTROMETRY [J].
CASTILLO, JR ;
MIR, JM ;
BENDICHO, C .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1988, 332 (07) :783-786
[4]   EFFECT OF MATRIX COMPONENTS ON CHROMIUM ATOMIZATION PROCESSES IN GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
CASTILLO, JR ;
MIR, JM ;
BENDICHO, C .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1988, 43 (03) :263-271
[5]   PICOSECOND LASER-PULSE INDUCED EFFECTS IN BISMUTH-TELLURITE, BI2TEO5 [J].
FOLDVARI, I ;
PETER, A ;
POWELL, RC ;
TAHERI, B .
OPTICAL MATERIALS, 1995, 4 (2-3) :299-303
[6]   GROWTH AND PROPERTIES OF BI2TEO5 SINGLE-CRYSTALS [J].
FOLDVARI, I ;
PETER, A ;
VOSZKA, R ;
KAPPERS, LA .
JOURNAL OF CRYSTAL GROWTH, 1990, 100 (1-2) :75-77
[7]   PHOTOREFRACTIVE EFFECTS IN BI2TEO5 SINGLE-CRYSTALS [J].
FOLDVARI, I ;
SCRIPSICK, MP ;
HALLIBURTON, LE ;
PETER, A .
PHYSICS LETTERS A, 1991, 154 (1-2) :84-86
[8]   MECHANISMS OF VAPORIZATION FOR CR USING ELECTROTHERMAL ATOMIZATION [J].
FONSECA, RW ;
WOLFE, KI ;
HOLCOMBE, JA .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1994, 49 (04) :399-408
[9]   A NEW FURNACE DESIGN FOR CONSTANT TEMPERATURE ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROSCOPY [J].
FRECH, W ;
JONSSON, S .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1982, 37 (12) :1021-1028
[10]   EFFECTS OF MODIFIER MASS AND TEMPERATURE-GRADIENTS ON ANALYTE SENSITIVITY IN ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY - INVITED LECTURE [J].
FRECH, W ;
LI, K ;
BERGLUND, M ;
BAXTER, DC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (02) :141-145