A voxel-based investigation for MRI-only radiotherapy of the brain using ultra short echo times

被引:87
作者
Edmund, Jens M. [1 ]
Kjer, Hans M. [2 ]
Van Leemput, Koen [2 ,3 ]
Hansen, Rasmus H. [4 ]
Andersen, Jon A. L. [1 ]
Andreasen, Daniel [1 ,2 ]
机构
[1] Copenhagen Univ Hosp, Dept Oncol, Radiotherapy Res Unit, Herlev, Denmark
[2] Tech Univ Denmark, Dept Appl Math & Comp Sci, DK-2800 Lyngby, Denmark
[3] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Dept Radiol, Boston, MA USA
[4] Copenhagen Univ Hosp, Dept Radiol, Herlev, Denmark
关键词
radiotherapy; MRI; imaging; MRI-only; pseudo CT; radiation therapy; substitute CT; MAGNETIC-RESONANCE; ATTENUATION-CORRECTION; QUALITY-ASSURANCE; ION RADIOTHERAPY; CT; PROSTATE; IMAGES; HEAD; CLASSIFICATION; SEGMENTATION;
D O I
10.1088/0031-9155/59/23/7501
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Radiotherapy (RT) based on magnetic resonance imaging (MRI) as the only modality, so-called MRI-only RT, would remove the systematic registration error between MR and computed tomography (CT), and provide co-registered MRI for assessment of treatment response and adaptive RT. Electron densities, however, need to be assigned to the MRI images for dose calculation and patient setup based on digitally reconstructed radiographs (DRRs). Here, we investigate the geometric and dosimetric performance for a number of popular voxel-based methods to generate a so-called pseudo CT (pCT). Five patients receiving cranial irradiation, each containing a co-registered MRI and CT scan, were included. An ultra short echo time MRI sequence for bone visualization was used. Six methods were investigated for three popular types of voxel-based approaches; (1) threshold-based segmentation, (2) Bayesian segmentation and (3) statistical regression. Each approach contained two methods. Approach 1 used bulk density assignment of MRI voxels into air, soft tissue and bone based on logical masks and the transverse relaxation time T-2 of the bone. Approach 2 used similar bulk density assignments with Bayesian statistics including or excluding additional spatial information. Approach 3 used a statistical regression correlating MRI voxels with their corresponding CT voxels. A similar photon and proton treatment plan was generated for a target positioned between the nasal cavity and the brainstem for all patients. The CT agreement with the pCT of each method was quantified and compared with the other methods geometrically and dosimetrically using both a number of reported metrics and introducing some novel metrics. The best geometrical agreement with CT was obtained with the statistical regression methods which performed significantly better than the threshold and Bayesian segmentation methods (excluding spatial information). All methods agreed significantly better with CT than a reference water MRI comparison. The mean dosimetric deviation for photons and protons compared to the CT was about 2% and highest in the gradient dose region of the brainstem. Both the threshold based method and the statistical regression methods showed the highest dosimetrical agreement. Generation of pCTs using statistical regression seems to be the most promising candidate for MRI-only RT of the brain. Further, the total amount of different tissues needs to be taken into account for dosimetric considerations regardless of their correct geometrical position.
引用
收藏
页码:7501 / 7519
页数:19
相关论文
共 55 条
[1]  
Amichetti M, 2012, RADIAT ONCOL, V7, P42
[2]  
Andreasen D, 2013, RAD ONCOL S2, V106, ps229, DOI DOI 10.1016/S0167-8140(15)32899-1
[3]  
[Anonymous], 2010, J ICRU, V10, P27, DOI 10.1093/jicru/ndq008
[4]  
[Anonymous], 1993, 49 ICRU
[5]   Whole-body PET/MRI: The effect of bone attenuation during MR-based attenuation correction in oncology imaging [J].
Aznar, M. C. ;
Sersar, R. ;
Saabye, J. ;
Ladefoged, C. N. ;
Andersen, F. L. ;
Rasmussen, J. H. ;
Lofgren, J. ;
Beyer, T. .
EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (07) :1177-1183
[6]  
Berker Y, 2012, J NUCL MED, V53, P1496
[7]   SmcHD1, containing a structural-maintenance-of-chromosomes hinge domain, has a critical role in X inactivation [J].
Blewitt, Marnie E. ;
Gendrel, Anne-Valerie ;
Pang, Zhenyi ;
Sparrow, Duncan B. ;
Whitelaw, Nadia ;
Craig, Jeffrey M. ;
Apedaile, Anwyn ;
Hilton, Douglas J. ;
Dunwoodie, Sally L. ;
Brockdorff, Neil ;
Kay, Graham F. ;
Whitelaw, Emma .
NATURE GENETICS, 2008, 40 (05) :663-669
[8]   Random forests [J].
Breiman, L .
MACHINE LEARNING, 2001, 45 (01) :5-32
[9]   Toward Implementing an MRI-Based PET Attenuation-Correction Method for Neurologic Studies on the MR-PET Brain Prototype [J].
Catana, Ciprian ;
van der Kouwe, Andre ;
Benner, Thomas ;
Michel, Christian J. ;
Hamm, Michael ;
Fenchel, Matthias ;
Fischl, Bruce ;
Rosen, Bruce ;
Schmand, Matthias ;
Sorensen, A. Gregory .
JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (09) :1431-1438
[10]   Target delineation in post-operative radiotherapy of brain gliomas: Interobserver variability and impact of image registration of MR (pre-operative) images on treatment planning CT scans [J].
Cattaneo, GM ;
Reni, M ;
Rizzo, G ;
Castellone, P ;
Ceresoli, GL ;
Cozzarini, C ;
Ferreri, AJM ;
Passoni, P ;
Calandrino, R .
RADIOTHERAPY AND ONCOLOGY, 2005, 75 (02) :217-223