Comparison of serum folate species analyzed by LC-MS/MS with total folate measured by microbiologic assay and Bio-Rad radioassay

被引:67
作者
Fazili, Zia [1 ]
Pfeiffer, Christine M. [1 ]
Zhang, Mindy [1 ]
机构
[1] Ctr Dis Control & Prevent, Div Sci Lab, Natl Ctr Environm Hlth, Atlanta, GA 30345 USA
关键词
D O I
10.1373/clinchem.2006.078451
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: The Bio-Rad QuantaPhase 11 radioassay (BR), used for 25 years to measure total folate (TFOL) concentrations for the National Health and Nutrition Examination Survey (NHANES), will be discontinued in 2007. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) or a microbiologic assay (MA) will be used in the future. Methods: We measured folate species by LC-MS/MS and TFOL by MA and BR in 327 serum samples. Results: LC-MS/MS measured 5-methyltetrahydrofolic acid (5CH(3)THF; 82%), folic acid (FA; 8%), 5-formyltetrahydrofolic acid (5CHOTHF; 6%), tetrahydrofolic acid (THF; 4%), and 5,10-methenyltetrahydrofolic acid (5,10CH=THF; 0%). The sum of the folate species correlated well with TFOL measured by MA (R-2 = 0.97) and BR (R-2 = 0.91). Compared with LC-MS/MS results, MA and BR values were significantly lower (-6% and -29%, respectively); however, these differences were concentration dependent. The MA almost completely recovered folates added to serum samples except for FA [69% (3%)] and THF [36% (10%)]. The BR underrecovered 5CH(3)THF [61% (9%)] and 5CHOTHF [38% (14%)] and overrecovered 5,10CH=THF [234% (32%)]. Multiple linear regression models with log-transformed data yielded a good fit for converting BR data to MA or LC-MS/MS data and MA data to LC-MS/MS data. Conclusions: The good correspondence between the sum of folate species determined by LC-MS/MS and TFOL determined by MA makes these 2 assays interchangeable. The BR produces much lower results, on average, probably because of 5CH(3)THF underrecovery. The conversion equations provided could be used for future NHANES time trend analyses. (c) 2007 American Association for Clinical Chemistry.
引用
收藏
页码:781 / 784
页数:4
相关论文
共 10 条
[1]  
Blackmore S, 2005, CLIN CHIM ACTA, V355, pS459
[2]   Measurement of Folates in serum and conventionally prepared whole blood lysates: Application of an automated 96-well plate isotope-dilution tandem mass spectrometry method [J].
Fazili, Z ;
Pfeiffer, CM .
CLINICAL CHEMISTRY, 2004, 50 (12) :2378-2381
[3]  
LEVINE S, 1993, CLIN CHEM, V39, P2209
[4]  
*LIF SCI RES OFF, 1984, ASS FOL NUTR STAT US
[5]  
Molloy AM, 1997, METHOD ENZYMOL, V281, P43
[6]   MICROBIOLOGICAL ASSAY ON MICROTITRE PLATES OF FOLATE IN SERUM AND RED-CELLS [J].
OBROIN, S ;
KELLEHER, B .
JOURNAL OF CLINICAL PATHOLOGY, 1992, 45 (04) :344-347
[7]   Biochemical indicators of B vitamin status in the US population after folic acid fortification: results from the National Health and Nutrition Examination Survey 1999-2000 [J].
Pfeiffer, CM ;
Caudill, SP ;
Gunter, EW ;
Osterloh, J ;
Sampson, EJ .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 2005, 82 (02) :442-450
[8]   Determination of folate vitamers in human serum by stable-isotope-dilution tandem mass spectrometry and comparison with radioassay and microbiologic assay [J].
Pfeiffer, CM ;
Fazili, Z ;
McCoy, L ;
Zhang, M ;
Gunter, EW .
CLINICAL CHEMISTRY, 2004, 50 (02) :423-432
[9]  
Raiten DJ, 1995, J NUTR, V125, p1371S, DOI DOI 10.1093/JN/125.5.1371S
[10]   Development of a new standard reference material: SRM 1955 (homocysteine and folate in human serum) [J].
Satterfield, Mary B. ;
Sniegoski, Lorna T. ;
Sharpless, Katherine E. ;
Welch, Michael J. ;
Hornikova, Adriana ;
Zhang, Nien-Fan ;
Pfeiffer, Christine M. ;
Fazili, Zia ;
Zhang, Mindy ;
Nelson, Bryant C. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 385 (03) :612-622