Plasma-polymerized films for biosensors II

被引:30
作者
Muguruma, Hitoshi [1 ]
机构
[1] Shibaura Inst Technol, Dept Elect Engn, Koto Ku, Tokyo 1358548, Japan
关键词
biosensor; plasma-polymerized film;
D O I
10.1016/j.trac.2007.03.003
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Biosensors are devices that use a biological reaction for detecting target analytes by generating a quantifiable electronic signal. They are powerful tools used in medical diagnostics, food-quality control and environmental monitoring. A typical biosensor is an integrated product, incorporating biological elements and transducers. It has been consistently shown that plasma-polymerized thin films (PPFs), created in a glow-discharge or plasma-in-vapor phase, have potential for use as the interface between the two components of biosensors. This review mainly covers the developments in PPFs used for biosensor design since that previous review [H. Muguruma, I. Karube, Trends Anal. Chem. 18 (1999) 62]. To date, transducers have been amenable to miniaturization, and the concept of biosensors has concomitantly expanded to encompass microchips, arrayed sensors and nanotechnology. The role of dry-process-based PPFs in biosensor design has become increasingly more important. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:433 / 443
页数:11
相关论文
共 71 条
[1]   A new method for immunosensor preparation:: Atmospheric plasma torch [J].
Akdogan, Ebru ;
Cokeliler, Dilek ;
Marcinauskas, Liutauras ;
Valatkevicius, Pranas ;
Valincius, Vitas ;
Mutlu, Mehmet .
SURFACE & COATINGS TECHNOLOGY, 2006, 201 (06) :2540-2546
[2]   Glow-discharge-treated cellulose acetate (CA) membrane for a high linearity single-layer glucose electrode in the food industry [J].
Alp, B ;
Mutlu, S ;
Mutlu, M .
FOOD RESEARCH INTERNATIONAL, 2000, 33 (02) :107-112
[3]   Electrochemical sensors [J].
Bakker, E .
ANALYTICAL CHEMISTRY, 2004, 76 (12) :3285-3298
[4]   Plasma-polymerized coatings for bio-MEMS applications [J].
Bouaidat, S ;
Winther-Jensen, B ;
Christensen, SF ;
Jonsmann, J .
SENSORS AND ACTUATORS A-PHYSICAL, 2004, 110 (1-3) :390-394
[5]   BIOCHEMICAL ASPECTS OF BIOSENSORS [J].
BYFIELD, MP ;
ABUKNESHA, RA .
BIOSENSORS & BIOELECTRONICS, 1994, 9 (4-5) :373-400
[6]   FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE [J].
CASS, AEG ;
DAVIS, G ;
FRANCIS, GD ;
HILL, HAO ;
ASTON, WJ ;
HIGGINS, IJ ;
PLOTKIN, EV ;
SCOTT, LDL ;
TURNER, APF .
ANALYTICAL CHEMISTRY, 1984, 56 (04) :667-671
[7]  
CHEN Q, 2004, CHEM MATER, V16, P2852
[8]   Plasma-surface modification of biomaterials [J].
Chu, PK ;
Chen, JY ;
Wang, LP ;
Huang, N .
MATERIALS SCIENCE & ENGINEERING R-REPORTS, 2002, 36 (5-6) :143-206
[9]   ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY [J].
CLARK, LC ;
LYONS, C .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1962, 102 (01) :29-&
[10]  
Çökeliler D, 2002, ANAL CHIM ACTA, V469, P217