Attenuation and backscatter estimation using video signal analysis applied to B-mode images

被引:52
作者
Knipp, BS
Zagzebski, JA
Wilson, TA
Dong, F
Madsen, EL
机构
[1] Univ Wisconsin, Dept Med Phys, Madison, WI 53706 USA
[2] Univ Wisconsin, Dept Radiol, Madison, WI 53706 USA
[3] Univ Wisconsin, Dept Human Oncol, Madison, WI 53706 USA
关键词
attenuation; backscatter; B-mode imaging; phantoms; quantitative imaging; tissue characterization;
D O I
10.1177/016173469701900305
中图分类号
O42 [声学];
学科分类号
070206 [声学]; 082403 [水声工程];
摘要
Most methods for in vivo quantitation of ultrasound attenuation and backscatter are not available clinically because they rely upon acquiring and analyzing radio frequency (rf) echo signals. This paper describes a technique to estimate ultrasound attenuation and backscatter from B-mode image data. The video signal analysis (VSA) technique utilizes images of a reference phantom, taken using the same instrument settings used to record images from the patient or sample, to account for effects of the transducer beam, system gain and signal processing on image data. A 'gray-scale look-up table' is derived to convert image pixel value data within a region of interest to echo signal amplitudes relative to echo signals from the same depth in the reference phantom. These relative echo levels enable estimates of attenuation and backscatter in the region of interest. VSA was used to quantify acoustic properties of test phantoms using 3 different clinical scanners and various transducers. The level of agreement between results obtained with different ultrasound imaging systems was very good. VSA attenuation and backscatter levels also compare favorably with attenuation coefficients and backscatter coefficients obtained using rf analysis. (C) 1997 Dynamedia, Inc.
引用
收藏
页码:221 / 233
页数:13
相关论文
共 25 条
[1]
*AM I ULTR MED, 1991, STAND METH MEAS PERF
[2]
TESTS OF BACKSCATTER COEFFICIENT MEASUREMENT USING BROAD-BAND PULSES [J].
CHEN, JF ;
ZAGZEBSKI, JA ;
MADSEN, EL .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1993, 40 (05) :603-607
[3]
Garra B. S., 1993, ULTRASONIC SCATTERIN, P347
[4]
QUANTITATIVE ESTIMATION OF LIVER ATTENUATION AND ECHOGENICITY - NORMAL STATE VERSUS DIFFUSE LIVER-DISEASE [J].
GARRA, BS ;
INSANA, MF ;
SHAWKER, TH ;
RUSSELL, MA .
RADIOLOGY, 1987, 162 (01) :61-67
[5]
PARAMETRIC ULTRASOUND IMAGING FROM BACKSCATTER COEFFICIENT MEASUREMENTS - IMAGE-FORMATION AND INTERPRETATION [J].
INSANA, MF ;
HALL, TJ .
ULTRASONIC IMAGING, 1990, 12 (04) :245-267
[6]
COMPARISON OF THEORETICAL SCATTERING RESULTS AND ULTRASONIC DATA FROM CLINICAL LIVER EXAMINATIONS [J].
LIZZI, FL ;
KING, DL ;
RORKE, MC ;
HUI, J ;
OSTROMOGILSKY, M ;
YAREMKO, MM ;
FELEPPA, EJ ;
WAI, P .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1988, 14 (05) :377-385
[7]
LU Z, UNPUB ACAD RADIOLOGY
[8]
Ultrasound attenuation and backscatter in the liver during prednisone administration [J].
Lu, ZF ;
Zagzebski, JA ;
OBrien, RT ;
Steinberg, H .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (01) :1-8
[9]
LU ZF, 1995, J ULTRASOUND MED S3, V14, P88
[10]
MADSEN E L, 1978, Medical Physics (Woodbury), V5, P391, DOI 10.1118/1.594483