Model-based generation of low distortion currents in grid-coupled PWM-inverters using an LCL output filter

被引:11
作者
Bolsens, B [1 ]
De Brabandere, K [1 ]
Van den Keybus, J [1 ]
Driesen, J [1 ]
Belmans, R [1 ]
机构
[1] Catholic Univ Louvain, Dept Elect Engn, B-3001 Heverlee, Belgium
来源
PESC 04: 2004 IEEE 35TH ANNUAL POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-6, CONFERENCE PROCEEDINGS | 2004年
关键词
D O I
10.1109/PESC.2004.1354816
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this work, a single phase LCL output stage for grid coupled applications is built and evaluated. An accurate model and observer of the output filter and the distorted grid voltage is implemented. This paper deals with the construction of a 14-state model, and the feedback control loop to obtain good closed loop response. Simulations indicate a good performance of the controller, with a total harmonic current distortion (THD) below 1%. Experimental results confirm the simulations, and illustrate the good operation of the Kalman observer to estimate the distorted grid voltage (THD 3%). The output filter effectively reduces the PWM harmonics in the grid current.
引用
收藏
页码:4616 / 4622
页数:7
相关论文
共 10 条
[1]   New trends in active filters for power conditioning [J].
Akagi, H .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1996, 32 (06) :1312-1322
[2]  
BOLSENS B, 2002, P IEE PEMD 2002 BATH
[3]  
de Souza FP, 2000, IEEE POWER ELECTRON, P500, DOI 10.1109/PESC.2000.878912
[4]  
Franklin G.F., 1998, Digital Control of Dynamics Systems, V3rd ed.
[5]   A DIGITAL RECURSIVE MEASUREMENT SCHEME FOR ONLINE TRACKING OF POWER-SYSTEM HARMONICS [J].
GIRGIS, AA ;
CHANG, WB ;
MAKRAM, EB .
IEEE TRANSACTIONS ON POWER DELIVERY, 1991, 6 (03) :1153-1160
[6]  
Lindgren M, 1998, IEEE POWER ELECTRON, P229, DOI 10.1109/PESC.1998.701904
[7]  
MENDALEK N, 2001, P IEEE PESC 2001 VAN
[8]  
MEYR H, 1992, REGELUNGSTECHNIK SYS
[9]  
PONNALURI S, 2001, P IEEE PESC 2001 VAN
[10]  
WANG TC, 2003, P IEEE PESC 2003 AC