Developing methods to evaluate odour control products

被引:7
作者
Bouzalakos, S [1 ]
Jefferson, S
Longhurst, PJ
Stuetz, RM
机构
[1] Cranfield Univ, Integrated Waste Management Ctr, Cranfield MK43 0AL, Beds, England
[2] Cranfield Univ, Sch Water Sci, Cranfield MK43 0AL, Beds, England
[3] Univ New S Wales, Sch Civil & Environm Engn, Ctr Water & Waste Technol, Sydney, NSW 2052, Australia
关键词
gas absorption; hydrogen sulphide; mass transfer; odour control products; spray tower;
D O I
10.2166/wst.2004.0269
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
An economical and practical alternative to the standard end-of-pipe odour control methods is the application of liquid odour control products. Currently, there are no established product-testing methods. The data that are available are often of questionable quality and may have limited relevance to waste management. Waste facilities receive differing streams of waste at varying loading volumes. Whilst in operation this exposes control products to a wide variety of environmental conditions, further increasing the difficulty of selecting an effective means of control. The current study initially identifies commercially available odour control products applicable for solid and liquid waste management operations. Bench-scale batch absorption tests have been carried out to investigate odorous gas abatement for a range of selected commercial products and water at a range of pH values. Hydrogen sulphide was the test odorous gas, as it is commonly associated with waste processes. Gas-phase volumetric mass-transfer coefficients (K(G)a) have been calculated to determine mass-transfer performance. The development of a pilot-scale spray tower is then presented as the testing apparatus for future work. This is an attempt to construct a repeatable testing method for evaluating abatement performance of odour control products, and control the problems encountered when applying odour control products to open sites. K(G)a values and data collected from tests in this study will be considered in future work as design parameters for the rig.
引用
收藏
页码:225 / 232
页数:8
相关论文
共 15 条
[1]  
*ASCE, 1995, WEF MAN PRACT ASCE M
[2]   Developments in odour control and waste gas treatment biotechnology: a review [J].
Burgess, JE ;
Parsons, SA ;
Stuetz, RM .
BIOTECHNOLOGY ADVANCES, 2001, 19 (01) :35-63
[3]  
CHEREMISINOFF PN, 1998, IND ODOUR CONTROL
[4]  
Danckwerts P.V., 1970, GAS LIQUID REACTIONS
[5]  
*EA, 2002, HOR GUID OD 2
[6]  
ELINSKY SE, 1974, P SPEC C STAT OF THE, P88
[7]   Absorption of gases in spray towers [J].
Hixson, AW ;
Scott, CE .
INDUSTRIAL AND ENGINEERING CHEMISTRY, 1935, 27 :307-314
[8]  
HOBSON J, 1999, 3400 WRC UC
[9]  
JEFFERSON B, 2002, P OD MAN TREATM ODOU
[10]  
Lewicki R. A., 2000, P WAST 2000 WAST MAN, P515