Electrical cardioversion for persistent atrial fibrillation or atrial flutter in clinical practice: predictors of long-term outcome

被引:38
作者
Boriani, G. [1 ]
Diemberger, I. [1 ]
Biffi, M. [1 ]
Domenichini, G. [1 ]
Martignani, C. [1 ]
Valzania, C. [1 ]
Branzi, A. [1 ]
机构
[1] Univ Bologna, Azienda Osped S Orsola Malpighi, Inst Cardiol, Bologna, Italy
关键词
D O I
10.1111/j.1742-1241.2007.01298.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Despite the results of Atrial Fibrillation Follow-up Investigation of Rhythm Management and Rate Control versus Electrical Cardioversion for Persistent Atrial Fibrillation trials, which favour a general shift in atrial fibrillation (AF) therapeutic approach towards control of ventricular rate, a strategy based on restoration of sinus rhythm could still play a role in selected patients at lower risk of AF recurrence. We explored possible predictors of relapses after external electrical cardioversion among patients with persistent AF or atrial flutter (AFL). We analysed the clinical characteristics and conventional echocardiographic parameters of patients with persistent AF/AFL enrolled in an institutional electrical cardioversion programme. Among 242 patients (AF/AFL, 195/47; mean age 62 +/- 13 years), sinus rhythm was restored in 215 (89%) and maintained in 73 (34%) at a follow-up of 930 days (median). No baseline clinical/echocardiographic variables predicted acute efficacy of cardioversion at logistic regression analysis. However, two variables predicted long-term AF/AFL recurrence among patients with successful cardioversion at multivariate Cox's proportional hazards analysis: (i) duration of arrhythmia >= 1 year (HR, 2.07; 95% CI, 1.29-3.33) and (ii) presence of previous cardioversion (HR, 1.67; 95% CI, 1.17-2.38). These variables also presented high-positive predictive values (72% and 80% respectively). Whereas the high acute efficacy of electrical cardioversion (approximately 90%) does not appear to be predictable, two simple clinical variables could help identify patients at higher risk of long-term AF/AFL recurrence after successful electrical cardioversion. We think there could be a case for initially attempting external electrical cardioversion to patients who have had AF/AFL for < 1 year. In such patients, the chance of long-term success appears to be relatively high.
引用
收藏
页码:748 / 756
页数:9
相关论文
共 37 条
[1]  
Barbaro V, 2001, Ann Ist Super Sanita, V37, P377
[2]  
Blomstrom-Lundqvist Carina, 2003, Journal of the American College of Cardiology, V42, P1493, DOI 10.1016/j.jacc.2003.08.013
[3]   PROPAFENONE FOR CONVERSION OF RECENT-ONSET ATRIAL-FIBRILLATION - A CONTROLLED COMPARISON BETWEEN ORAL LOADING DOSE AND INTRAVENOUS ADMINISTRATION [J].
BORIANI, G ;
CAPUCCI, A ;
LENZI, T ;
SANGUINETTI, M ;
MAGNANI, B .
CHEST, 1995, 108 (02) :355-358
[4]   Rate control in atrial fibrillation - Choice of treatment and assessment of efficacy [J].
Boriani, G ;
Biffi, M ;
Diemberger, I ;
Martignani, C ;
Branzi, A .
DRUGS, 2003, 63 (14) :1489-1509
[5]   A CONTROLLED-STUDY ON ORAL PROPAFENONE VERSUS DIGOXIN PLUS QUINIDINE IN CONVERTING RECENT-ONSET ATRIAL-FIBRILLATION TO SINUS RHYTHM [J].
CAPUCCI, A ;
BORIANI, G ;
RUBINO, I ;
DELLACASA, S ;
SANGUINETTI, M ;
MAGNANI, B .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 1994, 43 (03) :305-313
[6]   Randomized trials of rate vs. rhythm control for atrial fibrillation [J].
Chung, MK .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2004, 10 (01) :45-53
[7]   Relationships between sinus rhythm, treatment, and survival in the atrial fibrillation follow-up investigation of rhythm management (AFFIRM) study [J].
Corley, SD ;
Epstein, AE ;
DiMarco, JP ;
Domanski, MJ ;
Geller, N ;
Greene, HL ;
Josephson, RA ;
Kellen, JC ;
Klein, RC ;
Krahn, AD ;
Mickel, M ;
Mitchell, LB ;
Nelson, JD ;
Rosenberg, Y ;
Schron, E ;
Shemanski, L ;
Waldo, AL ;
Wyse, DG .
CIRCULATION, 2004, 109 (12) :1509-1513
[8]   Clinical factors associated with abandonment of a rate-control or a rhythm-control strategy for the management of atrial fibrillation in the AFFIRM study [J].
Curtis, AB ;
Seals, AA ;
Safford, RE ;
Slater, W ;
Tullo, NG ;
Vidaillet, JH ;
Wilber, DJ ;
Slee, A .
AMERICAN HEART JOURNAL, 2005, 149 (02) :304-308
[9]   Factors influencing long term persistence of sinus rhythm after a first electrical cardioversion for atrial fibrillation [J].
Duytschaever, M ;
Haerynck, F ;
Tavernier, R ;
Jordaens, L .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (01) :284-287
[10]   Relapse and mortality following cardioversion of new-onset vs. recurrent atrial fibrillation and atrial flutter in the elderly [J].
Elesber, AA ;
Rosales, AG ;
Herges, RM ;
Shen, WK ;
Moon, BS ;
Malouf, JF ;
Ammash, NM ;
Somers, V ;
Hodge, DO ;
Gersh, BJ ;
Hammill, SC ;
Friedman, PA .
EUROPEAN HEART JOURNAL, 2006, 27 (07) :854-860