Simultaneous multielemental determination using a low-resolution inductively coupled plasma spectrometer diode array detection system

被引:12
作者
Pimentel, MF
Neto, BD
de Araujo, MCU
Pasquini, C
机构
[1] Fundacao Inst Tecnol Estado Pernambuco, BR-50740540 Recife, PE, Brazil
[2] Univ Fed Pernambuco, CCEN, Dept Quim Fundamental, BR-50739907 Recife, PE, Brazil
[3] Univ Fed Paraiba, CCEN, Dept Quim, BR-58059900 Joao Pessoa, Paraiba, Brazil
[4] Univ Estadual Campinas, UNICAMP, Inst Quim, BR-13081970 Campinas, SP, Brazil
关键词
multivariate calibration; plasma emission spectrometry; photodiode array;
D O I
10.1016/S0584-8547(97)00091-8
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
This work presents a versatile method for simultaneous multielemental analysis using detection with photodiode arrays and multivariate calibration techniques. A multidetection system based on an array of 1024 photodiodes was built and adapted to a commercial plasma emission scanning spectrometer. Spectral data were acquired at low resolution, allowing simultaneous monitoring of a broad spectral range and resulting in very informative but considerably overlapped spectra. Partial least squares and principal component regressions were employed to minimize overlapping problems. A numerical procedure for window selection was also developed. The new method was applied to the simultaneous determination of manganese, molybdenum, nickel, chromium and iron in steel samples, resulting in average relative prediction errors of 2.1% for Mn, 3.4% for Mo, 0.6% for Cr, 1.5% for Ni and 0.8% for Fe. These errors are comparable to those observed with conventional scanning detection systems and separate univariate calibrations, but the new method allows simultaneous determination of the five elements, with data acquisition significantly faster than in scanning instruments, (C) 1997 Elsevier Science B.V.
引用
收藏
页码:2151 / 2161
页数:11
相关论文
共 39 条
[1]   ELIMINATION OF INTERFERENCES AND EFFECTS FROM DRIFT IN WORKING PARAMETERS IN INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY BY USING A COMBINATION OF THE GENERALIZED STANDARD ADDITION METHOD AND THE GENERALIZED INTERNAL REFERENCE METHOD [J].
ALAMMAR, AS ;
HAMID, HA ;
RASHID, BH .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1990, 45 (4-5) :359-366
[2]   SOLID-STATE DETECTOR FOR ICP-OES [J].
BARNARD, TW ;
CROCKETT, MI ;
IVALDI, JC ;
LUNDBERG, PL ;
YATES, DA ;
LEVINE, PA ;
SAUER, DJ .
ANALYTICAL CHEMISTRY, 1993, 65 (09) :1231-1239
[3]   DESIGN AND EVALUATION OF AN ECHELLE GRATING OPTICAL-SYSTEM FOR ICP-OES [J].
BARNARD, TW ;
CROCKETT, MI ;
IVALDI, JC ;
LUNDBERG, PL .
ANALYTICAL CHEMISTRY, 1993, 65 (09) :1225-1230
[4]   DETERMINATION OF TRACES OF BORON IN REFRACTORY AND OTHER METALS OF HIGH-PURITY [J].
BAUER, G ;
REHANA, I ;
WEGSCHEIDER, W ;
ORTNER, HM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1988, 43 (08) :971-982
[5]   MULTICOMPONENT STANDARD ADDITIONS AND PARTIAL LEAST-SQUARES MODELING - A MULTIVARIATE CALIBRATION APPROACH TO THE RESOLUTION OF SPECTRAL INTERFERENCES IN GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
BAXTER, DC ;
OHMAN, J .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1990, 45 (4-5) :481-491
[6]   Determination of gadolinium in geological samples by inductively coupled plasma mass spectrometry and multivariate calibration [J].
Behrens, A .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1995, 50 (12) :1521-1530
[7]  
BELATTO CR, 1996, J AUTOM CHEM, V18, P7
[8]   APPLICATION OF A PHOTODIODE ARRAY DETECTOR TO AN ARC SPECTROGRAPH [J].
BRETT, L ;
STAHL, RG ;
TIMMINS, KJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1989, 4 (04) :333-336
[9]  
BUSCH KW, 1990, MULTIELEMENT DETECTI
[10]  
Cornell J.A, 1990, RUN MIXTURE EXPT PRO