Determinants of Significant Paravalvular Regurgitation After Transcatheter Aortic Valve Implantation Impact of Device and Annulus Discongruence

被引:317
作者
Detaint, Delphine [1 ]
Lepage, Laurent [1 ]
Himbert, Dominique [1 ]
Brochet, Eric [1 ]
Messika-Zeitoun, David [1 ]
Iung, Bernard [1 ]
Vahanian, Alec [1 ]
机构
[1] Hop Xavier Bichat, Dept Cardiol, F-75018 Paris, France
关键词
annulus; aortic regurgitation; transcatheter aortic valve implantation; PROSTHESIS-PATIENT MISMATCH; HIGH-RISK PATIENTS; EUROPEAN-SOCIETY; CLINICAL IMPACT; HEART-VALVE; STENOSIS; REPLACEMENT; MANAGEMENT; SEVERITY; POSITION;
D O I
10.1016/j.jcin.2009.07.003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives The aim of this study was to assess prosthesis/annulus discongruence and its impact on the occurrence of significant aortic regurgitation (AR) immediately after transcatheter aortic valve implantation (TAVI). Background Paravalvular AR might occur after TAVI, but its determinants remain unclear. Methods Comprehensive echocardiographic examinations were performed in 74 patients who underwent TAVI with a balloon expandable device. Congruence between annulus and device was appraised with the cover index: 100 x (prosthesis diameter - transesophageal echocardiography annulus diameter)/prosthesis diameter. Results At baseline aortic valve area was 0.67 +/- 0.2 cm(2), and mean gradient was 50 15 mm Hg. The TAVI used transfemoral approach in 46 patients (62%) and transapical access in 28 (38%). Prosthesis size was 23 mm in 24 patients (34%) and 26 mm in 50 patients (66%). After TAVI, paravalvular AR was absent in 5 patients (7%), graded 1/4 in 53 (72%), 2/4 in 12 (16%), and 3/4 in 4 (5%). Occurrence of AR >= 2/4 was related to greater patient height, larger annulus, and smaller cover index (all p < 0.002) but not to ejection fraction, severity of stenosis, or prosthesis size. AR >= 2/4 was never observed in patients with aortic annulus <22 mm or with a cover index >8%. Significant improvements were observed from the first 20 cases (AR >= 2/4, 40%) to the last 54 (AR >= 2/4, 15%) (p = 0.02). In multivariate analysis, independent predictors of AR >= 2/4 were low cover index (odds ratio: 1.22; per confidence interval: 1.03 to 1.51 per 1% decrease, p = 0.02) and first versus last procedures (odds ratio: 2.24; 95% confidence interval: 1.07 to 5.22, p = 0.03). Conclusions Our study shows that the occurrence of AR >= 2/4 is related to prosthesis/annulus discongruence even after adjustment for experience. Hence, to minimize paravalvular AR, appropriate annular measurements and prosthesis sizing are critical. (J Am Coll Cardiol Intv 2009;2:821-7) (C) 2009 by the American College of Cardiology Foundation
引用
收藏
页码:821 / 827
页数:7
相关论文
共 31 条
  • [1] American College of Cardiology, 2006, J Am Coll Cardiol, V48, pe1, DOI 10.1016/j.jacc.2006.05.021
  • [2] BARBALIAROS VC, 2008, JACC-CARDIOVASC INTE, V1, P580
  • [3] Early experience with percutaneous transcatheter implantation of heart valve prosthesis for the treatment of end-stage inoperable patients with calcific aortic stenosis
    Cribier, A
    Eltchaninoff, H
    Tron, C
    Bauer, F
    Agatiello, C
    Sebagh, L
    Bash, A
    Nusimovici, D
    Litzler, PY
    Bessou, JP
    Leon, MB
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (04) : 698 - 703
  • [4] Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis - First human case description
    Cribier, A
    Eltchaninoff, H
    Bash, A
    Borenstein, N
    Tron, C
    Bauer, F
    Derumeaux, G
    Anselme, F
    Laborde, F
    Leon, MB
    [J]. CIRCULATION, 2002, 106 (24) : 3006 - 3008
  • [5] Treatment of calcific aortic stenosis with the percutaneous heart valve - Mid-term follow-up from the initial feasibility studies: The French experience
    Cribier, A
    Eltchaninoff, H
    Tron, C
    Bauer, F
    Agatiello, C
    Nercolini, D
    Tapiero, S
    Litzler, PY
    Bessou, JP
    Babaliaros, V
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (06) : 1214 - 1223
  • [6] Contemporary surgical or percutaneous management of severe aortic stenosis in the elderly
    Descoutures, Fleur
    Himbert, Dominique
    Lepage, Laurent
    Iung, Bernard
    Detaint, Delphine
    Tchetche, Didier
    Brochet, Eric
    Castier, Yves
    Depoix, Jean-Pol
    Nataf, Patrick
    Vahanian, Alec
    [J]. EUROPEAN HEART JOURNAL, 2008, 29 (11) : 1410 - 1417
  • [7] Percutaneous aortic valve replacement for severe aortic stenosis in high-rick patients using the second- and current third-generation self-expanding CoreValve prosthesis - Device success and 30-day clinical outcome
    Grube, Eberhard
    Schuler, Gerhard
    Buellesfeld, Lutz
    Gerckens, Ulrich
    Linke, Axel
    Wenaweser, Peter
    Sauren, Barthel
    Mohr, Friedrich-Wilhelm
    Walther, Thomas
    Zickmann, Bernfried
    Iversen, Stein
    Felderhoff, Thomas
    Cartier, Raymond
    Bonan, Raoul
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (01) : 69 - 76
  • [8] Percutaneous implantation of the CoreValve self-expanding valve prosthesis in high-risk patients with aortic valve disease - The Siegburg First-in-Man Study
    Grube, Eberhard
    Laborde, Jean C.
    Gerckens, Ulrich
    Felderhoff, Thomas
    Sauren, Barthel
    Buellesfeld, Lutz
    Mueller, Ralf
    Menichelli, Maurizio
    Schmidt, Thomas
    Zickmann, Bernfried
    Iversen, Stein
    Stone, Gregg W.
    [J]. CIRCULATION, 2006, 114 (15) : 1616 - 1624
  • [9] Prevalence and clinical significance of incidental paraprosthetic valvar regurgitation: a prospective study using transoesophageal echocardiography
    Ionescu, A
    Fraser, AG
    Butchart, EG
    [J]. HEART, 2003, 89 (11) : 1316 - 1321
  • [10] DOPPLER COLOR FLOW MAPPING IN THE EVALUATION OF PROSTHETIC MITRAL AND AORTIC-VALVE FUNCTION
    KAPUR, KK
    FAN, P
    NANDA, NC
    YOGANATHAN, AP
    GOYAL, RG
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 13 (07) : 1561 - 1571