Reproducibility of technetium-99m mercaptoacetyltriglycine clearance

被引:26
作者
Piepsz, A
Tondeur, M
Kinthaert, J
Ham, HR
机构
[1] Department of Radioisotopes, Hôpital Saint-Pierre, B-1000 Brussels, 322, Rue Haute
来源
EUROPEAN JOURNAL OF NUCLEAR MEDICINE | 1996年 / 23卷 / 02期
关键词
technetium-99m mercaptoacetyltriglycine; clearance; tubular function; precision; reproducibility;
D O I
10.1007/BF01731844
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this paper was to determine the reproducibility (precision) of technetium-99m mercaptoacetyltriglycine (MAG3) clearance and to compare it with that of chromium-51 ethylenediamine tetra-acetic acid (EDTA). Twelve young volunteers (aged between 21 and 34 years), without any history of medical problems, were enrolled in this study. The test was performed twice, at an interval of 8 days and under similar physiological conditions, After the intravenous injection of both tracers, 15 blood samples were taken between 3 and 240 min. A biexponential fit was adapted to the plasma disappearance curves (5- to 120-min samples for Tc-99m-MAG3 and 10- to 240-min samples for Cr-51-ED-TA); the clearances were calculated according to Sapirstein and corrected for body surface area. The mean clearance values were 110 (range 85-130) and 226 (range 109-319) ml/min/1.73 m(2), respectively, for Cr-51- EDTA and Tc-99m-MAG3. For Cr-51-EDTA clearance, the mean difference between the first and the second measurement was -2.1% of the mean of the two successive values (SD: 8.4%). In ten cases, the difference was less than 12%; in two cases, the differences were 15% and 18%, respectively. For Tc-99m-MAG3 clearance, the mean difference between the first and the second measurement was -20% of the mean of the two successive values (SD: 25%). In six cases, the difference was less than 12%; in four cases, between 15% and 40%; and in two cases, more than 60%. Methodological factors (impurites contained in the commercial kit, variable protein binding) as well as physiological factors (pH of urine, sodium load, stress) may explain the lack of precision of the (99m)TcMAG3 clearance, It is concluded that changes in Tc-99m-MAG3 plasma clearance should be interpreted with care in daily routine.
引用
收藏
页码:195 / 198
页数:4
相关论文
共 18 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]  
BRAUNER L, 1981, CLIN PHYSIOL, V1, P175, DOI 10.1111/j.1475-097X.1981.tb00885.x
[3]   PRECISION OF SINGLE INJECTION [CR-51]EDTA PLASMA CLEARANCE AND ENDOGENOUS CREATININE CLEARANCE DETERMINATIONS IN CHILDREN [J].
BROCHNERMORTENSEN, J ;
ROHBRANDT, K ;
LAURITZEN, RB .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1977, 37 (07) :625-629
[4]   SELECTION OF ROUTINE METHOD FOR DETERMINATION OF GLOMERULAR-FILTRATION RATE IN ADULT PATIENTS [J].
BROCHNERMORTENSEN, J ;
RODBRO, P .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1976, 36 (01) :35-43
[5]   RENAL CLEARANCE DETERMINATION WITH ONE BLOOD-SAMPLE - IMPROVED ACCURACY AND UNIVERSAL APPLICABILITY BY A NEW CALCULATION PRINCIPLE [J].
BUBECK, B .
SEMINARS IN NUCLEAR MEDICINE, 1993, 23 (01) :73-86
[6]   ALKALOSIS + RENAL P-AMINOHIPPURATE TRANSPORT IN DOG - RELATION TO LACTATE UPTAKE [J].
COHEN, JJ ;
RANDALL, EW .
AMERICAN JOURNAL OF PHYSIOLOGY, 1964, 206 (02) :383-&
[7]   SIMULTANEOUS DETERMINATION IN CHILDREN OF GLOMERULAR FILTRATION RATE AND EFFECTIVE RENAL PLASMA FLOW BY SINGLE INJECTION CLEARANCE TECHNIQUE [J].
DONATH, A .
ACTA PAEDIATRICA SCANDINAVICA, 1971, 60 (05) :512-&
[8]   CHANGES IN RENAL BLOOD FLOW AND POSSIBLY INTRARENAL DISTRIBUTION OF BLOOD DURING NATRIURESIS ACCOMPANYING SALINE LOADING IN DOG [J].
EARLEY, LE ;
FRIEDLER, RM .
JOURNAL OF CLINICAL INVESTIGATION, 1965, 44 (06) :929-&
[9]   TC-99M (TC-99M) MERCAPTOACETYLTRIGLYCINE - UPDATE ON THE NEW TC-99M RENAL TUBULAR FUNCTION AGENT [J].
ESHIMA, D ;
TAYLOR, A .
SEMINARS IN NUCLEAR MEDICINE, 1992, 22 (02) :61-73
[10]   GLOMERULAR-FILTRATION RATE MEASUREMENT BY SINGLE-SHOT INJECTION OF INULIN [J].
FLORIJN, KW ;
BARENDREGT, JNM ;
LENTJES, EGWM ;
VANDAM, W ;
PRODJOSUDJADI, W ;
VANSAASE, JLCM ;
VANES, LA ;
CHANG, PC .
KIDNEY INTERNATIONAL, 1994, 46 (01) :252-259