Improved isolation of Escherichia coli O157 using large enrichment volumes for immunomagnetic separation

被引:16
作者
Ogden, ID [1 ]
MacRae, M
Hepburn, NF
Strachan, NJC
机构
[1] Univ Aberdeen, Dept Med Microbiol, Appl Food Microbiol Grp, Aberdeen AB25 2ZD, Scotland
[2] Univ Aberdeen, Dept Plant & Soil Sci, Aberdeen AB25 2ZD, Scotland
关键词
D O I
10.1046/j.1472-765x.2000.00827.x
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The recovery of low numbers of Escherichia coli O157 in foods by immunomagnetic separation (IMS) was improved, on average, ninefold by increasing the enrichment volume tested from 1 to 10 ml while maintaining the volume of immunobeads constant at 0.02 ml. Although 50 mi volumes also gave improved recoveries (approximately threefold), the 50 ml volume cannot be recommended until a suitable magnetic separation apparatus has been developed. By testing 10 ml volumes, the improved sensitivity of the IMS procedure will reduce false-negative E. coli O157 tests and help improve epidemiological studies of this pathogen.
引用
收藏
页码:338 / 341
页数:4
相关论文
共 16 条
[1]  
AHMED S, 1977, 3 INT S WORKSH SHIG, P22
[2]  
[Anonymous], 1995, MORBIDITY MORTALITY, V44, P157
[3]   Numerical results and designing aspects concerning the HGMF filtering cells with bound flow field [J].
Badescu, V ;
Rotariu, O ;
Murariu, V ;
Rezlescu, N .
INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 1996, 22 (04) :797-805
[4]   AN OUTBREAK OF DIARRHEA AND HEMOLYTIC UREMIC SYNDROME FROM ESCHERICHIA-COLI O157-H7 IN FRESH-PRESSED APPLE CIDER [J].
BESSER, RE ;
LETT, SM ;
WEBER, JT ;
DOYLE, MP ;
BARRETT, TJ ;
WELLS, JG ;
GRIFFIN, PM .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1993, 269 (17) :2217-2220
[5]   USE OF SEMIAUTOMATIC PIPETTES IN VIABLE COUNTING OF BACTERIA [J].
BOUSFIEL.IJ ;
SMITH, GL ;
TRUEMAN, RW .
JOURNAL OF APPLIED BACTERIOLOGY, 1973, 36 (02) :297-&
[6]   A COMPARISON OF IMMUNOMAGNETIC SEPARATION AND DIRECT CULTURE FOR THE ISOLATION OF VEROCYTOTOXIN-PRODUCING ESCHERICHIA-COLI O157 FROM BOVINE FECES [J].
CHAPMAN, PA ;
WRIGHT, DJ ;
SIDDONS, CA .
JOURNAL OF MEDICAL MICROBIOLOGY, 1994, 40 (06) :424-427
[7]  
de W Blackburn C., 1991, BIOFOULING, V5, P143
[8]   Detection of Escherichia coli O157:H7 in ground beef in eight hours [J].
Gooding, CM ;
Choudary, PV .
JOURNAL OF MICROBIOLOGICAL METHODS, 1998, 34 (02) :89-98
[9]  
Jones DL, 1999, SOIL USE MANAGE, V15, P76, DOI 10.1111/j.1475-2743.1999.tb00069.x
[10]   IMMUNOMAGNETIC SEPARATION AS AN ALTERNATIVE TO ENRICHMENT BROTHS FOR SALMONELLA DETECTION [J].
MANSFIELD, LP ;
FORSYTHE, SJ .
LETTERS IN APPLIED MICROBIOLOGY, 1993, 16 (03) :122-125