Total knee arthroplasty after spontaneous osseous ankylosis and takedown of formal knee fusion

被引:42
作者
Kim, YH [1 ]
Kim, JS [1 ]
Cho, SH [1 ]
机构
[1] Ahn Sei Hosp, Joint Replacement Ctr Korea, Nam Gu, Seoul 135010, South Korea
关键词
total knee arthroplasty; formal knee fusion; spontaneous ankylosis; active flexion; active extension; knee infection; knee wound edge necrosis; V-Y quadricepsplasty;
D O I
10.1054/arth.2000.4640
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study compares the results of 16 total knee arthroplasties after a spontaneous osseous ankylosis and 14 total knee arthroplasties after a takedown of formal knee fusion. This series is a collection of patients who have either ankylosis or arthrodesis because of previous pyogenic or tuberculous infection. There were 18 women and 12 men. The age at operation ranged from 30 to 62 years (average, 42.9 years). The duration of ankylosis was longer in the patients in the spontaneous ankylosis group (19.7 years) than in the patients in the formally fused knee group (11.3 years). The duration from prior infection to arthroplasty was 12.4 years (range, 6-22 years) in the patients in the formally fused group and 20.4 years (range, 7-39 years) in the patients in the spontaneous ankylosis group. The original diagnosis was tuberculous arthritis in 14 knees and pyogenic arthritis in 16 knees. The average follow-up was 5.3 years (range, 5-6 years). Gender, age, diagnosis, and follow-up period were comparable in both groups. The preoperative Hospital for Special Surgery Knee Score was 60 in both groups, and the average knee score in both groups at the final follow-up was 73 (range, 67-75). Comparison of the patient's preoperative and postoperative ambulatory status revealed functional improvement in both groups. The average range of active flexion in both groups was 75.8 degrees (range, 70 degrees-95 degrees). The extension lag in both groups averaged 9 degrees (range, 0 degrees-20 degrees). The range of motion was approximately the same in both groups. The angular deformity was corrected to 0 degrees to 10 degrees of valgus angulation in all knees. There was no revised prosthesis for loosening at the final follow-up. Complications included skin edge necrosis (53.3%), pyogenic infection in 2 patients, and a quadriceps tendon rupture in 1 patient.
引用
收藏
页码:453 / 460
页数:8
相关论文
共 8 条
[1]  
Aglietti P, 1989, J Arthroplasty, V4, P1, DOI 10.1016/S0883-5403(89)80046-4
[2]  
Bradley G W, 1987, J Arthroplasty, V2, P179, DOI 10.1016/S0883-5403(87)80035-9
[3]   Results of total knee arthroplasty following takedown of formal knee fusion [J].
Cameron, HU ;
Hu, C .
JOURNAL OF ARTHROPLASTY, 1996, 11 (06) :732-737
[4]  
HOLDEN DL, 1988, CLIN ORTHOP RELAT R, P223
[5]   COMPARISON OF 4 MODELS OF TOTAL KNEE-REPLACEMENT PROSTHESES [J].
INSALL, JN ;
RANAWAT, CS ;
AGLIETTI, P ;
SHINE, J .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1976, 58 (06) :754-765
[7]  
MULLEN JO, 1983, CLIN ORTHOP RELAT R, P200
[8]   TOTAL KNEE REPLACEMENT AFTER SPONTANEOUS OSSEOUS ANKYLOSIS - A REPORT OF 3 CASES [J].
SCHURMAN, JR ;
WILDE, AH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (03) :455-459