Depth dose-equivalent and effective energies of photoneutrons generated by 6-18 MV X-ray beams for radiotherapy

被引:70
作者
d'Errico, F
Luszik-Bhadra, M
Nath, R
Siebert, BRL
Wolf, U
机构
[1] Yale Univ, Sch Med, Dept Therapeut Radiol, New Haven, CT 06510 USA
[2] Phys Tech Bundesanstalt, D-38116 Braunschweig, Germany
[3] Univ Leipzig, Klin & Poliklin Strahlentherapie & Radioonkol, D-04103 Leipzig, Germany
来源
HEALTH PHYSICS | 2001年 / 80卷 / 01期
关键词
detector; etched-track; dose equivalent; Monte Carlo; neutrons;
D O I
10.1097/00004032-200101000-00003
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Photoneutron production was investigated on Siemens KD 2 and Varian Clinac accelerators operating in the 6-18 MV range. Neutron dose equivalent rates were measured on the surface of a water phantom at the isocenter of the accelerators and also inside the phantom at depths of 1, 5, and 10 cm and off-axis distances of 0, 20, and 50 cm. Superheated drop detectors based on dichlorofluoromethane and etched-track detectors with boronated converters were employed in this study. The energy response of these detectors permits a direct measurement of dose equivalent without prior knowledge of the neutron energy spectra. Dose equivalent rates were assessed using the Q(L) relationship from ICRP publication 60, as well as using earlier data from ICRP publication 21. This permitted both a comparison with previously published data and an assessment of the impact of the recent ICRP recommendations-which were found to increase the dose equivalent levels by about 30%. In addition, the depth corresponding to 50% of maximum dose equivalent, d(H50), was determined along the central axis of the beams and at 50 cm off-axis. Monte Carlo neutron transport calculations were performed to determine the depth-dose equivalent distributions in a phantom irradiated with monoenergetic neutrons. Effective energies of the photoneutron spectra were then estimated by comparing our measured d(H50) values to those calculated for monoenergetic neutrons. It was found that the effective photoneutron energy is 1.8-2.1 MeV within the 10-18 MV x-ray beams, and it is 0.5-0.8 MeV for photoneutrons transmitted through the accelerator head. Data from this work cover most of the x-ray beam energies in clinical use and permit an assessment of integral dose values as well as specific organ doses to a radiotherapy patient.
引用
收藏
页码:4 / 11
页数:8
相关论文
共 38 条
[1]   KERMA EQUIVALENT FACTOR FOR PHOTONS AND NEUTRONS UP TO 20 MEV [J].
ALEKSEEV, AG ;
GOLOVACHIK, VT ;
SAVINSKY, AK .
RADIATION PROTECTION DOSIMETRY, 1986, 14 (04) :289-298
[2]   PHOTONEUTRON PRODUCTION IN TISSUE DURING HIGH-ENERGY BREMSSTRAHLUNG RADIOTHERAPY [J].
ALLEN, PD ;
CHAUDHRI, MA .
PHYSICS IN MEDICINE AND BIOLOGY, 1988, 33 (09) :1017-1036
[3]  
[Anonymous], 38 NCRP
[4]  
[Anonymous], 1993, STOPPING POWERS RANG
[5]   SUPERHEATED DROP DETECTOR [J].
APFEL, RE .
NUCLEAR INSTRUMENTS & METHODS, 1979, 162 (1-3) :603-608
[6]  
APFEL RE, 1992, RADIAT PROT DOSIM, V44, P343
[7]   PHOSPHORUS ACTIVATION NEUTRON DOSIMETRY AND ITS APPLICATION TO AN 18-MV RADIOTHERAPY ACCELERATOR [J].
BADING, JR ;
ZEITZ, L ;
LAUGHLIN, JS .
MEDICAL PHYSICS, 1982, 9 (06) :835-843
[8]   Use of bubble detectors to measure neutron contamination of a medical accelerator photon beam [J].
Bourgois, L ;
Delacroix, D ;
Ostrowsky, A .
RADIATION PROTECTION DOSIMETRY, 1997, 74 (04) :239-246
[9]  
BRIESMEISTER J, 1991, 7396M LANL LA
[10]  
COYNE JJ, 1981, P 7 S MICR 1981 LOND, P689