Carboxyl-terminated dendrimer-coated bioactive interface for protein microarray: High-sensitivity detection of antigen in complex biological samples

被引:79
作者
Ajikumar, Parayil Kumaran
Kiat, Jin
Tang, Yew Chung
Lee, Jim Yang
Stephanopoulos, Gregory
Too, Heng-Phon
机构
[1] Natl Univ Singapore, Singapore MIT Alliance, MEBCS Program, Singapore 117546, Singapore
[2] MIT, Dept Chem Engn, Cambridge, MA 02139 USA
[3] Natl Univ Singapore, Yong Loo Lin Sch Med, Dept Biochem, Singapore 117597, Singapore
关键词
D O I
10.1021/la063717u
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Protein microarrays are promising tools that can potentially enable high throughput proteomic screening in areas such as disease diagnosis and drug discovery. A critical aspect in the development of protein microarrays is the optimization of the array's surface chemistry to achieve the high sensitivity required for detection of proteins in cell lysate and other complex biological mixtures. In the present study, a high-density antibody array with minimal nonspecific cellular protein adsorption was prepared using a glass surface coated with a poly(propyleneimine) dendrimer terminated with carboxyl group (PAMAM-COOH). The carboxyl-terminated dendrimer-modified surface has almost similar nonspecific cellular protein adsorption when compared to an inert PEG-modified surface. In addition, the multiple functional sites available for reaction on the dendrimer surface facilitated high-density immobilization of antibodies and efficient capture of bioanalytes. Various molecules were tested for their ability to block or deactivate the reactive carboxyl surface after antibody immobilization to further reduce the nonspecific binding. A short oligoethylene glycol (NH2-d4-PEG-COOH), was found to significantly improve the signal-to-noise ratio of the assay, resulting in higher sensitivity. The properties and functional qualities of the various surfaces were characterized by contact angle and AFM measurements. Nonspecific protein adsorption and protein immobilization as a function of dendrimer generations and sensitivity of antigen capturing from a buffer (1 pM) as well as from the complex cell lysate (10 pM) system were examined. Our detailed experimental studies demonstrated a facile method of preparing surfaces with high protein loading and low nonspecific protein binding for the development of high sensitivity protein microarrays.
引用
收藏
页码:5670 / 5677
页数:8
相关论文
共 84 条
[1]   Chemical strategies for functional proteomics [J].
Adam, GC ;
Sorensen, EJ ;
Cravatt, BF .
MOLECULAR & CELLULAR PROTEOMICS, 2002, 1 (10) :781-790
[2]   Mass spectrometry-based proteomics [J].
Aebersold, R ;
Mann, M .
NATURE, 2003, 422 (6928) :198-207
[3]   Preparation of DNA and protein micro arrays on glass slides coated with an agarose film [J].
Afanassiev, Victor ;
Hanemann, Vera ;
Woelfl, Stefan .
NUCLEIC ACIDS RESEARCH, 2000, 28 (12) :E66
[4]  
Ajikumar PK, 2005, ABSTR PAP AM CHEM S, V229, pU1106
[5]  
AJIKUMAR PK, IN PRESS INT J NANOS
[6]   A WATER-SOLUBLE, MONITORABLE PEPTIDE AND PROTEIN CROSS-LINKING AGENT [J].
ALDWIN, L ;
NITECKI, DE .
ANALYTICAL BIOCHEMISTRY, 1987, 164 (02) :494-501
[7]   Next generation of protein microarray support materials:: Evaluation for protein and antibody microarray applications [J].
Angenendt, P ;
Glökler, J ;
Sobek, J ;
Lehrach, H ;
Cahill, DJ .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1009 (1-2) :97-104
[8]   Toward optimized antibody microarrays:: a comparison of current microarray support materials [J].
Angenendt, P ;
Glökler, J ;
Murphy, D ;
Lehrach, H ;
Cahill, DJ .
ANALYTICAL BIOCHEMISTRY, 2002, 309 (02) :253-260
[9]   Progress in protein and antibody microarray technology [J].
Angenendt, P .
DRUG DISCOVERY TODAY, 2005, 10 (07) :503-511
[10]   Layer-by-layer construction of multilayer thin films composed of avidin and biotin-labeled poly(amine)s [J].
Anzai, J ;
Kobayashi, Y ;
Nakamura, N ;
Nishimura, M ;
Hoshi, T .
LANGMUIR, 1999, 15 (01) :221-226