Application of hand-held mobility spectrometers as sensors in manufacturing industries

被引:6
作者
Allinson, G [1 ]
机构
[1] Deakin Univ, Sch Aquat Sci & Nat Resources Management, Warrnambol, Vic 3280, Australia
来源
JOURNAL OF AUTOMATIC CHEMISTRY | 1998年 / 20卷 / 01期
关键词
D O I
10.1155/S1463924698000017
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Ion nobility spectrometers (IMS) are small, lightweight, extremely robust devices with low power requirements, no moving parts, no absolute requirement for gases or vacuums, that can be operated at ambient temperatures and pressures, and yet are capable of measuring vapour phase concentrations of organic chemicals at very low levels (sub-mu g/l). IMS are capable of analysing complex mixtures and producing a simple spectral output. Volatile components produce measurable negative and positive product ions in the spectrometer through chemical ionization. The spectra produced are essentially the vapour phase fingerprints of the target molecules/mixture. Quantitative data can be obtained provided instrument response is within the linear dynamic range of these instruments, but most practical applications of IMS have used the technology in a qualitative manner in situations which require just an above/below threshold or positive/negative response. In the manufacturing industry there are many examples where the aroma/odour of raw materials has safety or product quality implications. IMS was not developed to replace traditional methods of analysis, e.g. GC/IMS or sensory panels, but rather to provide a rapid, qualitative response complementary to more established methods. This paper reports on the use of a hand-held ion mobility spectrometer to characterize the vapours produced by volatile organic compounds,fresh herbs and retail spire mixtures at ambient temperature and pressure. The results show that by monitoring in both ion acquisition modes, ion mobility spectrometers are capable of discriminating between a wide range of products.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 30 条
[1]  
ALLINSON G, 1997, J FORENSIC SCI, V42, P311
[2]  
ALLINSON G, UNPUB
[3]   QUANTIFICATION OF MAMMALIAN LIGNANS IN BIOLOGICAL-FLUIDS USING GAS-CHROMATOGRAPHY WITH ION MOBILITY DETECTION [J].
ATKINSON, DA ;
HILL, HH ;
SHULTZ, TD .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 617 (02) :173-179
[4]   APPLICATION OF ION MOBILITY SPECTROMETRY TO SEMICONDUCTOR TECHNOLOGY - OUTGASSINGS OF ADVANCED POLYMERS UNDER THERMAL-STRESS [J].
BUDDE, KJ ;
HOLZAPFEL, WJ ;
BEYER, MM .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1995, 142 (03) :888-897
[5]  
EICEMAN GA, 1988, ANAL LETT, V21, P539
[6]   NEGATIVE-ION MOBILITY SPECTROMETRY FOR SELECTED INORGANIC POLLUTANT GASES AND GAS-MIXTURES IN AIR [J].
EICEMAN, GA ;
LEASURE, CS ;
VANDIVER, VJ .
ANALYTICAL CHEMISTRY, 1986, 58 (01) :76-80
[7]   MONITORING OF AIRBORNE ORGANIC VAPORS USING ION MOBILITY SPECTROMETRY [J].
EICEMAN, GA ;
SNYDER, AP ;
BLYTH, DA .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1990, 38 (03) :415-425
[8]  
EICEMAN GA, 1991, CRIT REV ANAL CHEM, V22, P17
[9]  
EICEMAN GA, 1994, ION MOBILITY SPECTRO
[10]  
*ENV TECHN GROUP I, CHEM DET ETGS IMS PR