Pore size distributions of cation-exchange adsorbents determined by inverse size-exclusion chromatography

被引:240
作者
DePhillips, P
Lenhoff, AM [1 ]
机构
[1] Univ Delaware, Dept Chem Engn, Newark, DE 19716 USA
[2] Merck Res Labs, W Point, PA 19486 USA
[3] Univ Delaware, Dept Chem & Biochem, Newark, DE 19716 USA
基金
美国国家科学基金会;
关键词
pore size distribution; inverse size-exclusion chromatography; cation-exchange adsorbents; stationary phases; LC; ion exchangers;
D O I
10.1016/S0021-9673(00)00420-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The pore dimensions, pore size distributions, and phase ratios were determined for a set of cation-exchange adsorbents using inverse size-exclusion chromatography (ISEC). The adsorbents examined represent a diverse set of materials from Pharmacia, TosoHaas, BioSepra, and EM Industries, which are widely used for protein purification. The ISEC was carried out using dextran standards with relative molecular masses of 180-6 105 000. This technique provided a comparative characterization of the accessible internal pore surface area, as a function of solute size, for the adsorbents tested. Adsorbent preparation strategies in which polymers are generated in situ or grafted onto base materials were found to have significant effects on pore dimensions and phase ratios. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:39 / 54
页数:16
相关论文
共 26 条
[1]   AGAROSE DOUBLE HELIX AND ITS FUNCTION IN AGAROSE-GEL STRUCTURE [J].
ARNOTT, S ;
FULMER, A ;
SCOTT, WE ;
DEA, ICM ;
MOORHOUSE, R ;
REES, DA .
JOURNAL OF MOLECULAR BIOLOGY, 1974, 90 (02) :269-&
[2]   Evaluation of microcapsule permeability via inverse size exclusion chromatography [J].
Brissova, M ;
Petro, M ;
Lacik, I ;
Powers, AC ;
Wang, T .
ANALYTICAL BIOCHEMISTRY, 1996, 242 (01) :104-111
[3]   Comparison of protein adsorption isotherms and uptake rates in preparative cation-exchange materials [J].
Chang, C ;
Lenhoff, AM .
JOURNAL OF CHROMATOGRAPHY A, 1998, 827 (02) :281-293
[4]   HINDERED TRANSPORT OF LARGE MOLECULES IN LIQUID-FILLED PORES [J].
DEEN, WM .
AICHE JOURNAL, 1987, 33 (09) :1409-1425
[5]   SIZE-EXCLUSION CHROMATOGRAPHY OF STRONG POLY-ELECTROLYTES ON POROUS-GLASS COLUMNS [J].
DUBIN, PL ;
TECKLENBURG, MM .
ANALYTICAL CHEMISTRY, 1985, 57 (01) :275-279
[6]   High-performance liquid chromatography of amino acids, peptides and proteins .96. Temperature-induced changes in the bandwidth behaviour of proteins separated with cation-exchange adsorbents [J].
Fang, FW ;
Aguilar, MI ;
Hearn, MTW .
JOURNAL OF CHROMATOGRAPHY A, 1996, 729 (1-2) :67-79
[7]   High-performance liquid chromatography of amino acids, peptides and proteins .93. Influence of temperature on the retention behaviour of proteins in cation-exchange chromatography [J].
Fang, FW ;
Aguilar, MI ;
Hearn, MTW .
JOURNAL OF CHROMATOGRAPHY A, 1996, 729 (1-2) :49-66
[8]   Study of physico-chemical properties of some packing materials .1. Measurements of the external porosity of packed columns by inverse size-exclusion chromatography [J].
Guan, H ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 1996, 731 (1-2) :27-40
[9]   Apparent pore size distributions of chromatography media [J].
Hagel, L ;
Ostberg, M ;
Andersson, T .
JOURNAL OF CHROMATOGRAPHY A, 1996, 743 (01) :33-42
[10]  
Hagel L., 1988, AQUEOUS SIZE EXCLUSI, P119