Outcomes after Internal versus External Tocodynamometry for Monitoring Labor

被引:50
作者
Bakker, Jannet J. H. [1 ]
Verhoeven, Corine J. M. [2 ]
Janssen, Petra F. [3 ]
van Lith, Jan M. [4 ,6 ]
van Oudgaarden, Elisabeth D. [5 ]
Bloemenkamp, Kitty W. M. [6 ]
Papatsonis, Dimitri N. M. [7 ]
Mol, Ben Willem J. [1 ,2 ]
van der Post, Joris A. M. [1 ]
机构
[1] Acad Med Ctr, Dept Obstet & Gynecol, NL-1100 DD Amsterdam, Netherlands
[2] Maxima Med Ctr, Veldhoven, Netherlands
[3] Vrije Univ Amsterdam Med Ctr, Amsterdam, Netherlands
[4] Onze Lieve Vrouw Hosp, Amsterdam, Netherlands
[5] Slotervaart Hosp, Amsterdam, Netherlands
[6] Leiden Univ, Med Ctr, Leiden, Netherlands
[7] Amphia Hosp Breda, Breda, Netherlands
关键词
INTRAUTERINE PRESSURE CATHETER; UTERINE RUPTURE; COMPLICATIONS; AUGMENTATION; TOCOGRAPHY;
D O I
10.1056/NEJMoa0902748
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND It has been hypothesized that internal tocodynamometry, as compared with external monitoring, may provide a more accurate assessment of contractions and thus improve the ability to adjust the dose of oxytocin effectively, resulting in fewer operative deliveries and less fetal distress. However, few data are available to test this hypothesis. METHODS We performed a randomized, controlled trial in six hospitals in the Netherlands to compare internal tocodynamometry with external monitoring of uterine activity in women for whom induced or augmented labor was required. The primary outcome was the rate of operative deliveries, including both cesarean sections and instrumented vaginal deliveries. Secondary outcomes included the use of antibiotics during labor, time from randomization to delivery, and adverse neonatal outcomes (defined as any of the following: an Apgar score at 5 minutes of less than 7, umbilical-artery pH of less than 7.05, and neonatal hospital stay of longer than 48 hours). RESULTS We randomly assigned 1456 women to either internal tocodynamometry (734) or external monitoring (722). The operative-delivery rate was 31.3% in the internal-tocodynamometry group and 29.6% in the external-monitoring group (relative risk with internal monitoring, 1.1; 95% confidence interval [CI], 0.91 to 1.2). Secondary outcomes did not differ significantly between the two groups. The rate of adverse neonatal outcomes was 14.3% with internal monitoring and 15.0% with external monitoring (relative risk, 0.95; 95% CI, 0.74 to 1.2). No serious adverse events associated with use of the intrauterine pressure catheter were reported. CONCLUSIONS Internal tocodynamometry during induced or augmented labor, as compared with external monitoring, did not significantly reduce the rate of operative deliveries or of adverse neonatal outcomes. (Current Controlled Trials number, ISRCTN13667534; Netherlands Trial number, NTR285.)
引用
收藏
页码:306 / 313
页数:8
相关论文
共 19 条
[1]  
American College of Obstetricians and Gynecologists, 2003, ACOG PRACTICE B, V102, P1445
[2]  
CHAN WH, 1973, OBSTET GYNECOL, V41, P7
[3]   INDUCTION OF LABOR - DOES INTERNAL TOCOGRAPHY RESULT IN BETTER OBSTETRIC OUTCOME THAN EXTERNAL TOCOGRAPHY [J].
CHIA, YT ;
ARULKUMARAN, S ;
SOON, SB ;
NORSHIDA, S ;
RATNAM, SS .
AUSTRALIAN & NEW ZEALAND JOURNAL OF OBSTETRICS & GYNAECOLOGY, 1993, 33 (02) :159-161
[4]  
CHUA S, 1990, OBSTET GYNECOL, V76, P164
[5]  
*DUTCH SOC OBST GY, 2008, 5 NVOG DUTCH SOC OBS
[6]   Uterine rupture after induction of labour in women with previous caesarean section (vol 112, pg 451, 2005) [J].
Kayani, SI ;
Alfirevic, Z .
BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2005, 112 (04) :528-528
[7]  
Liston RM, 2007, J OBSTET GYNAECOL CA, V29, P972
[8]   Fetal Health Surveillance: Antepartum and ntrapartum Consensus Guideline [J].
Liston, Robert ;
Sawchuck, Diane ;
Young, David ;
Brassard, Normand ;
Campbell, Kim ;
Davies, Greg ;
Ehman, William ;
Farine, Dan ;
Farquharson, Duncan ;
Hamilton, Emily ;
Helewa, Michael ;
Hughes, Owen ;
Lange, Ian ;
Martel, Jocelyne ;
Senikas, Vyta ;
Sprague, Ann ;
Wittmann, Bernd ;
Scrivener, Judy .
JOURNAL OF OBSTETRICS AND GYNAECOLOGY CANADA, 2007, 29 (09) :S3-S56
[9]   The 2008 National Institute of Child Health and Human Development workshop report on electronic fetal monitoring - Update on definitions, interpretation, and research guidelines [J].
Macones, George A. ;
Hankins, Gary D. V. ;
Spong, Catherine Y. ;
Hauth, John ;
Moore, Thomas .
OBSTETRICS AND GYNECOLOGY, 2008, 112 (03) :661-666
[10]  
MADANES AE, 1982, OBSTET GYNECOL, V59, P389