Automated analysis of myocardial deformation at dobutamine stress echocardiography - An angiographic validation

被引:85
作者
Ingul, Charlotte Bjork
Stoylen, Asbjorn
Slordahl, Stig A.
Wiseth, Rune
Burgess, Malcolm
Marwick, Thomas H. [1 ]
机构
[1] Univ Queensland, Sch Med, Princess Alexandra Hosp, Brisbane, Qld 4102, Australia
[2] Norwegian Univ Sci & Technol, Dept Circulat & Med Imaging, N-7034 Trondheim, Norway
基金
英国医学研究理事会;
关键词
D O I
10.1016/j.jacc.2007.01.059
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives We investigated the accuracy of automated analysis of myocardial deformation during dobutamine stress echocardiography (DSE). Background The time required for segmental measurement of strain rate imaging (SRI) limits its feasibility for quantification of DSE. Methods Myocardial deformation was assessed at DSE in 197 patients, 76 with and 61 without coronary artery disease (CAD) at angiography, and 60 at low risk of CAD. Automated deformation analysis was based on velocity gradient and segment length methods of measuring longitudinal motion within a region of interest tracked through the cardiac cycle. Results were compared with independent wall motion scoring (WMS). Patients were randomly divided; group A (n = 69) established optimal cutoffs for the parameters and group B (n = 68) tested their accuracy. Results The feasibility of WMS exceeded that of both SRI methods at rest and at peak stress. In group A, the area under the receiver-operating characteristics curve of the peak systolic strain rate was 0.90 by both methods, and the optimal cutoffs for detection of CAD were -1.3 (velocity gradient) and -1.2 s(-1) (segment length). The areas under the receiver-operating characteristics curves for end-systolic strain were less (0.87) by both methods, with respective cutoffs of 9% and 8%. In group B, the velocity and segment length methods had respective sensitivities of 87% and 84% for SR, and 87% and 88% for end-systolic strain. Both significantly exceeded that of WMS in the same group (75%). Conclusions Automated analysis of myocardial deformation at DSE is feasible and accurate, and may increase the sensitivity of expert conventional reading.
引用
收藏
页码:1651 / 1659
页数:9
相关论文
共 24 条
  • [1] Automatic timing of aortic valve closure in apical tissue Doppler images
    Aase, SA
    Stoylen, A
    Ingul, CB
    Frigstad, S
    Torp, H
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2006, 32 (01) : 19 - 27
  • [2] AASE SA, 2004, P IEEE ULTR S, V3, P2061
  • [3] Austen W G, 1975, Circulation, V51, P5
  • [4] A NOVEL METHOD FOR ANGLE INDEPENDENT ULTRASONIC-IMAGING OF BLOOD-FLOW AND TISSUE MOTION
    BOHS, LN
    TRAHEY, GE
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1991, 38 (03) : 280 - 286
  • [5] Development of a fully quantitative approach to the interpretation of stress echocardiography using radial and longitudinal myocardial velocities
    Cain, P
    Short, L
    Baglin, T
    Case, C
    Bosch, HG
    Marwick, TH
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2002, 15 (08) : 759 - 767
  • [6] Automated regional myocardial displacement for facilitating the interpretation of dobutamine echocardiography
    Cain, P
    Baglin, T
    Khoury, V
    Case, C
    Marwick, TH
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2002, 89 (12) : 1347 - 1353
  • [7] Assessment of regional long-axis function during dobutamine echocardiography
    Cain, P
    Marwick, TH
    Case, C
    Baglin, T
    Dart, J
    Short, L
    Olstad, B
    [J]. CLINICAL SCIENCE, 2001, 100 (04) : 423 - 432
  • [8] Effect of tissue Doppler on the accuracy of novice and expert interpreters of Dobutamine echocardiography
    Fathi, R
    Cain, P
    Nakatani, S
    Yu, HCM
    Marwick, TH
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2001, 88 (04) : 400 - 405
  • [9] Fraser A G, 2003, Eur J Echocardiogr, V4, P43, DOI 10.1053/euje.2002.0610
  • [10] Methodology, feasibility, safety and diagnostic accuracy of dobutamine stress echocardiography
    Geleijnse, ML
    Fioretti, PM
    Roelandt, JRTC
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (03) : 595 - 606