Low-Frequency Current Oscillations and Maximum Power Point Tracking in Grid-Connected Fuel-Cell-Based Systems

被引:56
作者
Giustiniani, Alessandro [1 ]
Petrone, Giovanni [1 ]
Spagnuolo, Giovanni [1 ]
Vitelli, Massimo [2 ]
机构
[1] Univ Salerno, Dipartimento Ingn Informaz & Ingn Elettr, I-84084 Salerno, Italy
[2] Univ Naples 2, Dept Informat Engn, I-81100 Caserta, Italy
关键词
Fuel cell (FC); low-frequency ripple rejection; maximum power point (MPP) tracking (MPPT); single-phase inverter control; CONVERTER; BEHAVIOR; STACK; MODEL;
D O I
10.1109/TIE.2009.2034175
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The study of a double-stage single-phase inverter for fuel-cell-based applications is proposed in this paper. A novel control strategy aimed at reducing the low-frequency oscillations of the fuel-cell (FC) current in order to guarantee the FC safety operating conditions is proposed. The reduction of such oscillations increases the FC lifetime and avoids high mechanical stress of the membrane and unnecessary consumption of reactants. Furthermore, it allows one to design a strategy for extracting the maximum power from the FC stack with a total control of the concentration losses. Simulation and experimental results confirm the effectiveness of the proposed approach.
引用
收藏
页码:2042 / 2053
页数:12
相关论文
共 32 条
  • [1] Modeling and analysis of transient behavior of polymer electrolyte membrane fuel cell hybrid vehicles
    Arsie, Ivan
    Di Domenico, Alfonso
    Pianese, Cesare
    Sorrentino, Marco
    [J]. JOURNAL OF FUEL CELL SCIENCE AND TECHNOLOGY, 2007, 4 (03): : 261 - 271
  • [2] The power performance curve for engineering analysis of fuel cells
    Benziger, JB
    Satterfield, MB
    Hogarth, WHJ
    Nehlsen, JP
    Kevrekidis, IG
    [J]. JOURNAL OF POWER SOURCES, 2006, 155 (02) : 272 - 285
  • [3] Chanasut N, 2008, 2008 IEEE IND APPL S, P1
  • [4] A dynamic model for a stand-alone PEM fuel cell power plant for residential applications
    El-Sharkh, MY
    Rahman, A
    Alam, MS
    Byrne, PC
    Sakla, AA
    Thomas, T
    [J]. JOURNAL OF POWER SOURCES, 2004, 138 (1-2) : 199 - 204
  • [5] Erikson R.W., 2001, Fundamentals of Power Electronics, V2nd
  • [6] Guidelines for the optimization of the P&O technique in grid-connected double-stage photovoltaic systems
    Femia, N.
    Fortunato, M.
    Lisi, G.
    Petrone, G.
    Spagnuolo, G.
    Vitelli, M.
    [J]. 2007 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, PROCEEDINGS, VOLS 1-8, 2007, : 2420 - +
  • [7] Optimization of perturb and observe maximum power point tracking method
    Femia, N
    Petrone, G
    Spagnuolo, G
    Vitelli, M
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2005, 20 (04) : 963 - 973
  • [8] Interactions between fuel cells and power converters: Influence of current harmonics on a fuel cell stack
    Fontes, Guillaume
    Turpin, Christophe
    Astier, Stephan
    Meynard, Thierry A.
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2007, 22 (02) : 670 - 678
  • [9] FUKUSHIMA K, 2009, P IEEE APEC, P447
  • [10] Analysis for the effect of inverter ripple current on fuel cell operating condition
    Gemmen, RS