Analysis of the partial charge reactions within a standby VRLA battery leading to an understanding of intermittent charging techniques

被引:7
作者
Muneret, X [1 ]
Coux, M [1 ]
Lenain, P [1 ]
机构
[1] ZI Est, F-62033 Arras, France
来源
INTELEC(R): TWENTY-SECOND INTERNATIONAL TELECOMMUNICATIONS ENERGY CONFERENCE | 2000年
关键词
D O I
10.1109/INTLEC.2000.884264
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Constant potential charging, either with a single voltage or with two voltage levels, is by far the most common float charging strategy. it is, however, a compromise since the voltage levels must be selected in order to both recharge and compensate for any self-discharge reactions and also to minimise the degree of positive grid corrosion, the usual failure mode of the battery under stationary operating conditions. Intermittent charging reduces overcharge and offers advantages for high temperature operation; however, the major risk is under-charge of the battery particularly of the negative electrode. This paper, by qualitative and quantitative consideration of the main electrochemical and chemical reactions in a valve-regulated lead-acid battery, attempts to estimate the gains and also the risks that could be expected by employing an intermittent charging technique that minimises the overcharge whilst maintaining the battery in a full state of charge.
引用
收藏
页码:293 / 298
页数:6
相关论文
共 7 条
[1]  
BRISSAUD C, 1997, INFLUENCE TIN LEVEL
[2]  
CUN JP, 1997, INCREASING UPS BATTE
[3]  
Dietrich Berndt, 1993, POWER SOURCES TECHNO
[4]  
LAMAN FC, 1998, ACCELERATED FAILURE
[5]  
LENAIN P, 1998, METHODS EVALUATION L
[6]  
LENAIN P, 1993, NEW TESTING METHODS
[7]  
PETERS K, 1970, POWER SOURCE, V2