Design of a triple resonance magic angle sample spinning probe for high field solid state nuclear magnetic resonance

被引:69
作者
Martin, RW [1 ]
Paulson, EK [1 ]
Zilm, KW [1 ]
机构
[1] Yale Univ, Dept Chem, New Haven, CT 06520 USA
关键词
D O I
10.1063/1.1571951
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Standard design and construction practices used in building nuclear magnetic resonance (NMR) probes for the study of solid state samples become difficult if not entirely impractical to implement as the H-1 resonance frequency approaches the self resonance frequency of commercial capacitors. We describe an approach that utilizes short variable transmission line segments as tunable reactances. Such an approach effectively controls stray reactances and provides a higher Q alternative to ceramic chip capacitors. The particular probe described is built to accommodate a 2.5 mm magic angle spinning rotor system, and is triply tuned to C-13, N-15, and H-1 frequencies for use at 18.8 T (200, 80, and 800 MHz, respectively). Isolation of the three radio frequency (rf) channels is achieved using both a rejection trap and a transmission line notch filter. The compact geometry of this design allows three channels with high power handling capability to fit in a medium bore (63 mm! magnet. Extended time variable temperature operation is integral to the mechanical design, enabling the temperature control necessary for investigation of biological macromolecules. Accurate measurement of the air temperature near the sample rotor is achieved using a fiber optic thermometer, which does not interfere with the rf electronics. We also demonstrate that acceptable line shapes are only readily achieved using zero magnetic susceptibility wire in construction of the sample coil. Computer simulation of the circuit aided in the physical design of the probe. Representative data illustrating the efficiency, rf homogeneity, and signal to noise factor of the probe are presented. (C) 2003 American Institute of Physics.
引用
收藏
页码:3045 / 3061
页数:17
相关论文
共 31 条
[1]   The influence of electrode geometry and gas flow on corona-to-glow and glow-to-spark threshold currents in air [J].
Akishev, Y ;
Goossens, O ;
Callebaut, T ;
Leys, C ;
Napartovich, A ;
Trushkin, N .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2001, 34 (18) :2875-2882
[2]  
*AM TECHN CER CORP, 1983, RF CAP HDB
[3]  
[Anonymous], 1962, INDUCTANCE CALCULATI
[4]   SINGLE COIL PROBE WITH TRANSMISSION-LINE TUNING FOR NUCLEAR MAGNETIC DOUBLE-RESONANCE [J].
CROSS, VR ;
HESTER, RK ;
WAUGH, JS .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1976, 47 (12) :1486-1488
[5]   A MULTI-NUCLEAR DOUBLE-TUNED PROBE FOR APPLICATIONS WITH SOLIDS OR LIQUIDS UTILIZING LUMPED TUNING ELEMENTS [J].
DOTY, FD ;
INNERS, RR ;
ELLIS, PD .
JOURNAL OF MAGNETIC RESONANCE, 1981, 43 (03) :399-416
[6]  
Doty FD, 1998, CONCEPT MAGNETIC RES, V10, P239, DOI 10.1002/(SICI)1099-0534(1998)10:4<239::AID-CMR2>3.0.CO
[7]  
2-Y
[8]  
Doty FD, 1998, CONCEPT MAGNETIC RES, V10, P133, DOI 10.1002/(SICI)1099-0534(1998)10:3<133::AID-CMR1>3.0.CO
[9]  
2-Y
[10]   THEORY OF HEAVY-HOLE MAGNETOEXCITONS IN GAAS-(AL,GA)AS QUANTUM-WELL HETEROSTRUCTURES [J].
DUGGAN, G .