Potential for potable water savings by using rainwater and greywater in a multi-storey residential building in southern Brazil

被引:157
作者
Ghisi, Enedir [1 ]
Ferreira, Daniel F. [1 ]
机构
[1] Univ Fed Santa Catarina, Dept Civil Engn, Lab Energy Efficiency Buildings, BR-88040900 Florianopolis, SC, Brazil
关键词
potable water savings; water end-uses; greywater; rainwater; multi-storey residential buildings;
D O I
10.1016/j.buildenv.2006.07.019
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Studies on the use of rainwater and greywater to promote potable water savings have been performed in different countries. The main objective of this article is to evaluate the potential for potable water savings by using rainwater and greywater in a multi-storey residential building composed of three blocks, located in Florianopolis, southern Brazil. Water end-uses were estimated by applying questionnaires and measuring water flow rates. An economic analysis was performed to evaluate the cost effectiveness of using rainwater and greywater either separately or together. Results show that the average potential for potable water savings range from 39.2% to 42.7% amongst the three blocks, considering that water for toilet flushing, clothes washing and cleaning does not need to be potable. By using rainwater, the potable water savings would actually range from 14.7% to 17.7%. When greywater is considered alone, potable water savings are higher, i.e., ranging from 28.7% to 34.8%. As for the use of rainwater and greywater combined, the potable water savings range from 36.7% to 42.0%. The main conclusion that can be made from the research is that the three systems that were investigated are cost effective as the payback periods were lower than 8 years, but the greywater system was the most cost effective one, followed closely by the rainwater one. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2512 / 2522
页数:11
相关论文
共 19 条
[1]  
ABNT (Associa?ao Brasileira De Normas T?cnicas), 1998, 5626 NBR
[2]   Greywater reuse: towards sustainable water management [J].
Al-Jayyousi, OR .
DESALINATION, 2003, 156 (1-3) :181-192
[3]  
[Anonymous], 2003, ESTATISTICA APLICADA
[4]   An investigation into greywater reuse for urban residential properties [J].
ChristovaBoal, D ;
Eden, RE ;
McFarlane, S .
DESALINATION, 1996, 106 (1-3) :391-397
[5]   Water saving potential of domestic water reuse systems using greywater and rainwater in combination [J].
Dixon, A ;
Butler, D ;
Fewkes, A .
WATER SCIENCE AND TECHNOLOGY, 1999, 39 (05) :25-32
[6]  
DIXON A, 2000, THESIS U LONDON
[7]   The use of rainwater for WC flushing: the field testing of a collection system [J].
Fewkes, A .
BUILDING AND ENVIRONMENT, 1999, 34 (06) :765-772
[8]   Economic feasibility of on-site greywater reuse in multi-storey buildings [J].
Friedler, E ;
Hadari, M .
DESALINATION, 2006, 190 (1-3) :221-234
[9]   Potential for potable water savings by using rainwater: An analysis over 62 cities in southern Brazil [J].
Ghisi, E ;
Montibeller, A ;
Schmidt, RW .
BUILDING AND ENVIRONMENT, 2006, 41 (02) :204-210
[10]  
GHISI E, 2004, NETUNO APROVEIAMENTO