The role of proton therapy in the treatment of large irradiation volumes: A comparative planning study of pancreatic and biliary tumors

被引:43
作者
Zurlo, A
Lomax, A
Hoess, A
Bortfeld, T
Russo, M
Goitein, G
Valentini, V
Marucci, L
Capparella, R
Loasses, A
机构
[1] Regina Elena Natl Canc Inst, Expert Syst Lab, I-00156 Rome, Italy
[2] Univ Rome Tor Vergata, Cattedra Radioterapia, Rome, Italy
[3] Paul Scherrer Inst, Dept Radiat Med, Villigen, Switzerland
[4] Deutsch Krebsforschungszentrum, Dept Med Phys, D-6900 Heidelberg, Germany
[5] Fdn TERA Adroterapia, Novara, Italy
[6] Univ Cattolica Sacro Cuore, Ist Radiol, Cattedra Radioterapia, Rome, Italy
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2000年 / 48卷 / 01期
关键词
comparative planning; conformal radiotherapy; protons; intensity-modulated photons;
D O I
10.1016/S0360-3016(00)00522-8
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The purpose of this study was to examine the potential benefit of proton therapy for abdominal tumors. Extensive comparative planning was conducted investigating the most up-to-date photon and proton irradiation technologies. Methods and Materials: A number of rival plans were generated for four patients: two inoperable pancreatic tumors, one inoperable and one postoperative biliary duct tumor. The dose prescription goal for these large targets was 50 Gy, followed by a boost dose up to 20 Gy to a smaller planning target volume (PTV). Photon plans were developed using "forward" planning of coplanar and noncoplanar conformal fields and "inverse" planning of intensity-modulated (IM) fields. Proton planning was simulated as administered using the so called spot-scanning technique. Plans were evaluated on the basis of normal tissues' dose-volume constraints (Emami B, Lyman J, Brown A, et al. Tolerance of normal tissue to therapeutic irradiation. Int J Radial Oncol Biol Phys 1990;21:109-122) and coverage of treatment volumes with prescribed doses. Results: For all cases, none of the forward calculated photon plans was able to deliver 50 Gy to large PTVs at the same time respecting the dose-volume constraints on all critical organs. Nine evenly spaced IM fields achieved or nearly achieved all maximum dose constraints to critical structures for two out of three inoperable patients. IM plans also obtained good results for the postoperative patient, even though the dose to the liver was very close to the maximum allowed. In all cases, photon irradiation of large PTV1s to 50 Gy followed by a 20 Gy boost entailed a risk very close to or higher than 5 % for serious complications to the kidneys, liver, or bowel. Simple arrangements of 2, 3, and 4 proton fields obtained better dose conformation to the target, allowing the delivery of planned doses including the boost to all patients, without excessive risk of morbidity. Dose homogeneity inside the targets was also superior with protons. Conclusion: For the irradiation of large PTVs located in the abdominal cavity, where multiple, parallel structured organs surround the target volumes, proton therapy, delivered with a sophisticated isocentric technique, has the potential to achieve superior dose distributions compared with state of-the-art photon irradiation techniques. IRI photon plans obtain better results in the postoperative case, because the reduced volume lessens the effect of the unavoidable increase of integral dose to surrounding tissues. (C) 2000 Elsevier Science Inc.
引用
收藏
页码:277 / 288
页数:12
相关论文
共 32 条
[1]  
[Anonymous], P 11 INT C US COMP R
[2]   CONSIDERATIONS IN FRACTIONATED PROTON RADIATION-THERAPY - CLINICAL POTENTIAL AND RESULTS [J].
AUSTINSEYMOUR, M ;
URIE, M ;
MUNZENRIDER, J ;
WILLETT, C ;
GOITEIN, M ;
VERHEY, L ;
GENTRY, R ;
MCNULTY, P ;
KOEHLER, A ;
SUIT, H .
RADIOTHERAPY AND ONCOLOGY, 1990, 17 (01) :29-35
[3]   REALIZATION AND VERIFICATION OF 3-DIMENSIONAL CONFORMAL RADIOTHERAPY WITH MODULATED FIELDS [J].
BORTFELD, T ;
BOYER, AL ;
SCHLEGEL, W ;
KAHLER, DL ;
WALDRON, TJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 30 (04) :899-908
[4]   Planning and delivering high doses to targets surrounding the spinal cord at the lower neck and upper mediastinal levels: Static beam-segmentation technique executed with a multileaf collimator [J].
DeNeve, W ;
DeWagter, C ;
DeJaeger, K ;
Thienpont, M ;
Colle, C ;
Derycke, S ;
Schelfhout, J .
RADIOTHERAPY AND ONCOLOGY, 1996, 40 (03) :271-279
[5]   Characterization of dose distribution in radiation therapy plans [J].
Dykstra, C ;
Bortfeld, T ;
Debus, J ;
Lomax, A ;
Harrop, R ;
Schlegel, W ;
Munkel, G .
RADIOTHERAPY AND ONCOLOGY, 1996, 41 (03) :281-284
[6]   TOLERANCE OF NORMAL TISSUE TO THERAPEUTIC IRRADIATION [J].
EMAMI, B ;
LYMAN, J ;
BROWN, A ;
COIA, L ;
GOITEIN, M ;
MUNZENRIDER, JE ;
SHANK, B ;
SOLIN, LJ ;
WESSON, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (01) :109-122
[7]   PATTERNS OF FAILURE IN GROSSLY RESECTED PANCREATIC DUCTAL ADENOCARCINOMA TREATED WITH ADJUVANT IRRADIATION +/- 5-FLUOROURACIL [J].
FOO, ML ;
GUNDERSON, LL ;
NAGORNEY, DM ;
MCLLRATH, DC ;
VANHEERDEN, JA ;
ROBINOW, JS ;
KVOLS, LK ;
GARTON, GR ;
MARTENSON, JA ;
CHA, SS .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 26 (03) :483-489
[8]  
FUKUMOTO S, 1989, P INT HEAV PART THER, P70
[9]  
HANKS GE, 1985, CANCER, V55, P2198, DOI 10.1002/1097-0142(19850501)55:9+<2198::AID-CNCR2820551423>3.0.CO
[10]  
2-7