Monitoring In Vivo Absorption of a Drug-Eluting Bioabsorbable Stent With Intravascular Ultrasound-Derived Parameters A Feasibility Study

被引:33
作者
Bruining, Nico [1 ]
de Winter, Sebastiaan [1 ]
Roelandt, Jos R. T. C. [1 ]
Regar, Evelyn [1 ]
Heller, Iddo [1 ]
van Domburg, Ron T. [1 ]
Hamers, Ronald [1 ]
Onuma, Yoshinobu [1 ]
Dudek, Darius [2 ]
Webster, Mark W. I. [3 ]
Thuesen, Leif [4 ]
Ormiston, John A. [3 ]
Cheong, Wai-Fung [5 ]
Miguel-Hebert, Karine [5 ]
Veldhof, Susan [5 ]
Serruys, Patrick W. [1 ]
机构
[1] Erasmus MC, Thoraxctr, Dept Cardiol, NL-3000 DR Rotterdam, Netherlands
[2] Jagiellonian Univ, Krakow, Poland
[3] Auckland City Hosp, Auckland, New Zealand
[4] Aarhus Univ Hosp, Skejby Sygehus, Skejby, Denmark
[5] Abbott Vasc, Diegem, Belgium
关键词
coronary artery disease; intravascular ultrasound; quantification; stents; QUANTITATIVE-ANALYSIS; PLAQUE COMPOSITION; CORONARY; IMPLANTATION; SIROLIMUS; DEGRADATION; SYSTEM; ABSORB; TRIAL;
D O I
10.1016/j.jcin.2010.02.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives The aim of this study was to investigate the feasibility of using quantitative differential echogenicity to monitor the in vivo absorption process of a drug-eluting poly-l-lactic-acid (PLLA) bioabsorbable stent (BVS, Abbott Vascular, Santa Clara, California). Background A new bioabsorbable, balloon-expanded coronary stent was recently evaluated in a first-in-man study. Little is known about the absorption process in vivo in diseased human coronary arteries. Methods In the ABSORB (Clinical Evaluation of the BVS everolimus eluting stent system) study, 30 patients underwent treatment with the BVS coronary stent system and were examined with intracoronary ultrasound (ICUS) after implantation, at 6 months and at 2-year follow-up. Quantitative ICUS was used to measure dimensional changes, and automated ICUS-based tissue composition software (differential echogenicity) was used to quantify plaque compositional changes over time in the treated regions. Results The BVS struts appeared as bright hyperechogenic structures and showed a continuous decrease of their echogenicity over time, most likely due to the polymer degradation process. In 12 patients in whom pre-implantation ICUS was available, at 2 years the percentage-hyperechogenic tissue was close to pre-implantation values, indicating that the absorption process was either completed or the remaining material was no longer differentially echogenic from surrounding tissues. Conclusions Quantitative differential echogenicity is a useful plaque compositional measurement tool. Furthermore, it seems to be valuable for monitoring the absorption process of bioabsorbable coronary stents made of semi-crystalline polymers. (J Am Coll Cardiol Intv 2010;3:449-56) (C) 2010 by the American College of Cardiology Foundation
引用
收藏
页码:449 / 456
页数:8
相关论文
共 23 条
[1]   Evaluation of four-year coronary artery response after sirolimus-eluting stent implantation using serial quantitative intravascular ultrasound and computer-assisted grayscale value analysis for plaque composition in event-free patients [J].
Aoki, J ;
Abizaid, AC ;
Serruys, PW ;
Ong, ATL ;
Boersma, E ;
Sousa, JE ;
Bruining, N .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (09) :1670-1676
[2]  
Bruining N, 1998, CATHETER CARDIO DIAG, V43, P254, DOI 10.1002/(SICI)1097-0304(199803)43:3<254::AID-CCD3>3.0.CO
[3]  
2-8
[4]  
Bruining N, 1995, COMPUT CARDIOL, P633, DOI 10.1109/CIC.1995.482744
[5]   Three-dimensional and quantitative analysis of atherosclerotic plaque composition by automated differential echogenicty [J].
Bruining, Nico ;
Verheye, Stefan ;
Knaapen, Michiel ;
Somers, Pamela ;
Roelandt, Jos R. T. C. ;
Regar, Evelyn ;
Heller, Iddo ;
de Winter, Sebstiaan ;
Ligthart, Jurgen ;
Van Langenhove, Glenn ;
de Feijter, Pim J. ;
Serruys, Patrick W. ;
Hamers, Ronald .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2007, 70 (07) :968-978
[6]  
Bruining Nico, 2008, EuroIntervention, V4, P285, DOI 10.4244/EIJV4I2A49
[7]   Stent thrombosis late after implantation of first-generation drug-eluting stents - A cause for concern [J].
Camenzind, Edoardo ;
Steg, P. Gabriel ;
Wijns, William .
CIRCULATION, 2007, 115 (11) :1440-1455
[8]   Retrospective image-based gating of intracoronary ultrasound images for improved quantitative analysis: The intelligate method [J].
de Winter, SA ;
Hamers, R ;
Degertekin, M ;
Tanabe, K ;
Lemos, PA ;
Serruys, PW ;
Roelandt, JRTC ;
Bruining, N .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2004, 61 (01) :84-94
[9]   Temporary scaffolding of coronary arteries with bioabsorbable magnesium stents:: a prospective, non-randomised multicentre trial [J].
Erbel, Raimund ;
Di Mario, Carlo ;
Bartunek, Jozef ;
Bonnier, Johann ;
de Bruyne, Bernard ;
Eberli, Franz R. ;
Erne, Paul ;
Haude, Michael ;
Heublein, Bernd ;
Horrigan, Mark ;
Ilsley, Charles ;
Boese, Dirk ;
Koolen, Jacques ;
Luescher, Thomas F. ;
Weissman, Neil ;
Waksman, Ron .
LANCET, 2007, 369 (9576) :1869-1875
[10]   Assessment of the absorption process following bioabsorbable everolimus-eluting stent implantation: temporal changes in strain values and tissue composition using intravascular ultrasound radiofrequency data analysis A substudy of the ABSORB clinical trial [J].
Garcia-Garcia, Hector M. ;
Gonzalo, Nieves ;
Pawar, Ravindra ;
Kukreja, Neville ;
Dudek, Dariusz ;
Thuesen, Leif ;
Ormiston, John A. ;
Regar, Evelyn ;
Serruys, Patrick W. .
EUROINTERVENTION, 2009, 4 (04) :443-448