Phase-contrast X-ray imaging combining free space propagation and Bragg diffraction

被引:39
作者
Coan, P [1 ]
Pagot, E [1 ]
Fiedler, S [1 ]
Cloetens, P [1 ]
Baruchel, J [1 ]
Bravin, A [1 ]
机构
[1] European Synchrotron Radiat Facil, F-38043 Grenoble, France
关键词
phase contrast; X-ray imaging; Fresnel diffraction; analyzers; X-ray source coherence;
D O I
10.1107/S0909049504028444
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The combination of X-ray 'propagation-based' and 'analyzer-based' phase-contrast imaging with a perfect crystal-analyzer is investigated. The image pattern produced using this 'hybrid' imaging technique presents peculiar features that can be interpreted as a mixture of the two independent phase-contrast signals. A quantitative analysis has been performed in terms of signal-to-noise ratio for the three techniques considered in this paper. Results show that in the 'hybrid imaging' technique this parameter has a weaker dependence on the angular alignment of the crystal analyser with respect to the 'analyser-based' imaging. This pioneering experiment indicates that this hybrid imaging technique might permit simultaneous advantage of the specific features of the two imaging methods to be taken.
引用
收藏
页码:241 / 245
页数:5
相关论文
共 23 条
[1]  
[Anonymous], IMAGE ANAL STEREO S1
[2]   Mammography with synchrotron radiation: Phase-detection techniques [J].
Arfelli, F ;
Bonvicini, V ;
Bravin, A ;
Cantatore, G ;
Castelli, E ;
Dalla Palma, L ;
Di Michiel, M ;
Fabrizioli, M ;
Longo, R ;
Menk, RH ;
Olivo, A ;
Pani, S ;
Pontoni, D ;
Poropat, P ;
Prest, M ;
Rashevsky, A ;
Ratti, M ;
Rigon, L ;
Tromba, G ;
Vacchi, A ;
Vallazza, E ;
Zanconati, F .
RADIOLOGY, 2000, 215 (01) :286-293
[3]  
Born M., 1999, PRINCIPLES OPTICS EL
[4]   Exploiting the x-ray refraction contrast with an analyser: the state of the art [J].
Bravin, A .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2003, 36 (10A) :A24-A29
[5]   Diffraction enhanced x-ray imaging [J].
Chapman, D ;
Thomlinson, W ;
Johnston, RE ;
Washburn, D ;
Pisano, E ;
Gmur, N ;
Zhong, Z ;
Menk, R ;
Arfelli, F ;
Sayers, D .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (11) :2015-2025
[6]   Phase objects in synchrotron radiation hard x-ray imaging [J].
Cloetens, P ;
Barrett, R ;
Baruchel, J ;
Guigay, JP ;
Schlenker, M .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1996, 29 (01) :133-146
[7]  
CLOETENS P, 1999, THESIS VRIJE U BRUSS
[8]   Differential x-ray phase contrast imaging using a shearing interferometer [J].
David, C ;
Nöhammer, B ;
Solak, HH ;
Ziegler, E .
APPLIED PHYSICS LETTERS, 2002, 81 (17) :3287-3289
[9]   X-RAY IMAGE-CONTRAST FROM A SIMPLE PHASE OBJECT [J].
DAVIS, TJ ;
GUREYEV, TE ;
GAO, D ;
STEVENSON, AW ;
WILKINS, SW .
PHYSICAL REVIEW LETTERS, 1995, 74 (16) :3173-3176
[10]  
Evans A.L., 1981, The Evaluation of Medical Images