Microemulsion electrokinetic chromatography applied for separation of levetiracetam from other antiepileptic drugs in polypharmacy

被引:33
作者
Ivanova, M
Piunti, A
Marziali, E
Komarova, N
Raggi, MA
Kenndler, E
机构
[1] Univ Vienna, Inst Analyt Chem, A-1090 Vienna, Austria
[2] LUMEX Ltd, St Petersburg, Russia
[3] Univ Bologna, Dept Pharmaceut Sci, I-40126 Bologna, Italy
关键词
antiepileptic drugs; microemulsion electrokinetic chromatography polypharmacy;
D O I
10.1002/elps.200390143
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Microemulsion electrokinetic chromatography was applied for the separation of levetiracetam from other antiepileptic drugs (primidone, phenobarbital, phenytoin, lamotrigine and carbamazepine) that are potentially coadministered in therapy of patients. The influence of the composition of the microemulsion system (with sodium dodecyl sulfate as charged surfactant) was investigated, modifying the kind of cosurfactant (lower alcohols from C3 to C5), the pH (and salinity) of the aqueous background electrolyte and the ratio of aqueous phase to organic constituents forming the microdropleis of the oil-in-water emulsion. Separation selectivity was depending on all these parameters, resulting even in changes of the migration sequence of the analytes. Only moderate correlation was observed for the microemulsion system compared with a micellar system, both consisting of the aqueous borate buffer (pH 9.2) and SDS as micelle former (linear correlation coefficient for analyte mobilities is 0.974). The sample solvent plays an important role on the shape of the resulting chromatograms: methanol at concentrations higher than 35% impairs peak shape and separation efficiency. The microemulsion method (with 93.76% aqueous borate buffer (pH 9.2, 10 mm), 0.48% n-octane, 1.80% SDS, 3.96% 1-butanol, all w/w) is suitable for the determination of levetiracetam in human plasma (combined with a sample pretreatment based on solid-phase extraction).
引用
收藏
页码:992 / 998
页数:7
相关论文
共 26 条
[1]  
Albert A., 1984, DETERMINATION IONIZA
[2]   Application of microemulsion electrokinetic chromatography to the analysis of a wide range of pharmaceuticals and excipients [J].
Altria, KD .
JOURNAL OF CHROMATOGRAPHY A, 1999, 844 (1-2) :371-386
[3]   Background theory and applications of microemulsion electrokinetic chromatography [J].
Altria, KD .
JOURNAL OF CHROMATOGRAPHY A, 2000, 892 (1-2) :171-186
[4]  
Gabel-Jensen C, 2001, ELECTROPHORESIS, V22, P1330, DOI 10.1002/1522-2683(200105)22:7<1330::AID-ELPS1330>3.0.CO
[5]  
2-D
[6]   Efficacy and safety of levetiracetam in children with partial seizures: An open-label trial [J].
Glauser, TA ;
Pellock, JM ;
Bebin, EM ;
Fountain, NB ;
Ritter, FJ ;
Jensen, CM ;
Shields, WD .
EPILEPSIA, 2002, 43 (05) :518-524
[7]   Microemulsion electrokinetic chromatography - or solvent-modified micellar electrokinetic chromatography? [J].
Hansen, SH ;
Gabel-Jensen, C ;
El-Sherbiny, DTM ;
Pedersen-Bjergaard, S .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2001, 20 (11) :614-619
[8]   Enantioselective analysis of levetiracetam and its enantiomer R-α-ethyl-2-oxo-pyrrolidine acetamide using gas chromatography and ion trap mass spectrometric detection [J].
Isoherranen, N ;
Roeder, M ;
Soback, S ;
Yagen, B ;
Schurig, V ;
Bialer, M .
JOURNAL OF CHROMATOGRAPHY B, 2000, 745 (02) :325-332
[9]  
Ivanova M, 2002, J SEP SCI, V25, P863, DOI 10.1002/1615-9314(20021001)25:14<863::AID-JSSC863>3.0.CO
[10]  
2-F