Off-pump coronary artery bypass grafting: Not a flash in the pan

被引:51
作者
Ascione, R [1 ]
Caputo, M [1 ]
Angelini, GD [1 ]
机构
[1] Bristol Royal Infirm & Gen Hosp, Bristol Heart Inst, Bristol BS2 8HW, Avon, England
关键词
D O I
10.1016/S0003-4975(02)04020-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
During the past decade, technical improvements have made off-pump coronary artery bypass operations a routine procedure. During this time, off-pump coronary artery bypass has been audited against conventional techniques by many observational, case-matched, and prospective randomized studies. There is evidence in the literature suggesting that off-pump coronary artery bypass operations reduce postoperative morbidity, organ dysfunction, and costs, without compromising midterm outcome compared with conventional coronary operations. The available evidence also supports the view that high-risk patients might benefit the most from revascularization on the beating heart. High quality follow-up data are still needed to assess the impact of off-pump coronary artery bypass operations on long-term clinical outcome (C) 2003 by The Society of Thoracic Surgeons.
引用
收藏
页码:306 / 313
页数:8
相关论文
共 89 条
[1]   CARDIAC TROPONIN-I - A MARKER WITH HIGH SPECIFICITY FOR CARDIAC INJURY [J].
ADAMS, JE ;
BODOR, GS ;
DAVILAROMAN, VG ;
DELMEZ, JA ;
APPLE, FS ;
LADENSON, JH ;
JAFFE, AS .
CIRCULATION, 1993, 88 (01) :101-106
[2]   Early and midterm outcome after off-pump and on-pump surgery in Beating Heart Against Cardioplegic Arrest Studies (BHACAS 1 and 2): a pooled analysis of two randomised controlled trials [J].
Angelini, GD ;
Taylor, FC ;
Reeves, BC ;
Ascione, R .
LANCET, 2002, 359 (9313) :1194-1199
[3]   TO USE OR NOT TO USE PUMP OXYGENATOR IN CORONARY-BYPASS OPERATIONS [J].
ANKENEY, JL .
ANNALS OF THORACIC SURGERY, 1975, 19 (01) :108-109
[4]   Predictors of atrial fibrillation after conventional and beating heart coronary surgery - A prospective, randomized study [J].
Ascione, R ;
Caputo, M ;
Calori, G ;
Lloyd, CT ;
Underwood, MJ ;
Angelini, GD .
CIRCULATION, 2000, 102 (13) :1530-1535
[5]   Inflammatory response after coronary revascularization with or without cardiopulmonary bypass [J].
Ascione, R ;
Lloyd, CT ;
Underwood, MJ ;
Lotto, AA ;
Pitsis, AA ;
Angelini, GD .
ANNALS OF THORACIC SURGERY, 2000, 69 (04) :1198-1204
[6]   On-pump versus off-pump coronary revascularization: Evaluation of renal function [J].
Ascione, R ;
Lloyd, CT ;
Underwood, MJ ;
Gomes, WJ ;
Angelini, CD .
ANNALS OF THORACIC SURGERY, 1999, 68 (02) :493-498
[7]   Beating versus arrested heart revascularization: evaluation of myocardial function in a prospective randomized study [J].
Ascione, R ;
Lloyd, CT ;
Gomes, WJ ;
Caputo, M ;
Bryan, AJ ;
Angelini, GD .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1999, 15 (05) :685-690
[8]   Reduced postoperative blood loss and transfusion requirement after beating-heart coronary operations: A prospective randomized study [J].
Ascione, R ;
Williams, S ;
Lloyd, CT ;
Sundaramoorthi, T ;
Pitsis, AA ;
Angelini, GD .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2001, 121 (04) :689-696
[9]   Coronary revascularization with or without cardiopulmonary bypass in patients with preoperative nondialysis-dependent renal insufficiency [J].
Ascione, R ;
Nason, G ;
Al-Ruzzeh, S ;
Ko, C ;
Ciulli, F ;
Angelini, GD .
ANNALS OF THORACIC SURGERY, 2001, 72 (06) :2020-2025
[10]  
Barner HB, 1998, ANN THORAC SURG, V66, pS25