Real-time second-harmonic-generation microscopy based on a 2-GHz repetition rate Ti:sapphire laser

被引:95
作者
Chu, SW [1 ]
Liu, TM
Sun, CK
机构
[1] Natl Taiwan Univ, Grad Inst Electroopt Engn, Taipei 10617, Taiwan
[2] Natl Taiwan Univ, Inst Fisheries Sci, Taipei 10617, Taiwan
来源
OPTICS EXPRESS | 2003年 / 11卷 / 08期
关键词
D O I
10.1364/OE.11.000933
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The problem of weak harmonic generation signal intensity limited by photodamage probability in optical microscopy and spectroscopy could be resolved by increasing the repetition rate of the excitation light source. Here we demonstrate the first photomultiplier-based real-time second-harmonic-generation microscopy taking advantage of the strongly enhanced nonlinear signal from a high-repetition-rate Ti:sapphire laser. We also demonstrate that the photodamage possibility in common biological tissues can be efficiently reduced with this high repetition rate laser at a much higher average power level compared to the commonly used similar to80-MHz repetition rate lasers. (C) 2003 Optical Society of America.
引用
收藏
页码:933 / 938
页数:6
相关论文
共 19 条
[1]   Nuclear energy in the twenty-first century: Examination of a contentious subject [J].
Beck, PW .
ANNUAL REVIEW OF ENERGY AND THE ENVIRONMENT, 1999, 24 :113-137
[2]   High-resolution nonlinear optical imaging of live cells by second harmonic generation [J].
Campagnola, PJ ;
Wei, MD ;
Lewis, A ;
Loew, LM .
BIOPHYSICAL JOURNAL, 1999, 77 (06) :3341-3349
[3]   Nonlinear bio-photonic crystal effects revealed with multimodal nonlinear microscopy [J].
Chu, SW ;
Chen, IH ;
Liu, TM ;
Sun, CK ;
Lee, SP ;
Lin, BL ;
Cheng, PC ;
Kuo, MX ;
Lin, DJ ;
Liu, HL .
JOURNAL OF MICROSCOPY-OXFORD, 2002, 208 (03) :190-200
[4]   Multimodal nonlinear spectral microscopy based on a femtosecond Cr:forsterite laser [J].
Chu, SW ;
Chen, IH ;
Liu, TM ;
Chen, PC ;
Sun, CK ;
Lin, BL .
OPTICS LETTERS, 2001, 26 (23) :1909-1911
[5]   2-PHOTON LASER SCANNING FLUORESCENCE MICROSCOPY [J].
DENK, W ;
STRICKLER, JH ;
WEBB, WW .
SCIENCE, 1990, 248 (4951) :73-76
[6]   DIRECT OBSERVATION OF FERROELECTRIC DOMAINS IN TGS WITH SECOND-HARMONIC LIGHT [J].
DOLINO, G .
APPLIED PHYSICS LETTERS, 1973, 22 (04) :123-124
[7]   CONNECTIVE-TISSUE POLARITY - OPTICAL 2ND-HARMONIC MICROSCOPY, CROSSED-BEAM SUMMATION, AND SMALL-ANGLE SCATTERING IN RAT-TAIL TENDON [J].
FREUND, I ;
DEUTSCH, M ;
SPRECHER, A .
BIOPHYSICAL JOURNAL, 1986, 50 (04) :693-712
[8]   2ND-HARMONIC IMAGING IN SCANNING OPTICAL MICROSCOPE [J].
GANNAWAY, JN ;
SHEPPARD, CJR .
OPTICAL AND QUANTUM ELECTRONICS, 1978, 10 (05) :435-439
[9]  
GAVIN D, 2000, ENCY ANAL CHEM
[10]   Second-harmonic tomography of tissues [J].
Guo, YC ;
Ho, PP ;
Savage, H ;
Harris, D ;
Sacks, P ;
Schantz, S ;
Liu, F ;
Zhadin, N ;
Alfano, RR .
OPTICS LETTERS, 1997, 22 (17) :1323-1325