Synchrotron radiation X-ray powder diffractometer with a cylindrical imaging plate

被引:53
作者
Fujiwara, A
Ishii, K
Watanuki, T
Suematsu, H
Nakao, H
Ohwada, K
Fujii, Y
Murakami, Y
Mori, T
Kawada, H
Kikegawa, T
Shimomura, O
Matsubara, T
Hanabusa, H
Daicho, S
Kitamura, S
Katayama, C
机构
[1] Univ Tokyo, Sch Sci, Dept Phys, Bunkyo Ku, Tokyo 1130033, Japan
[2] Univ Tokyo, Inst Solid State Phys, Neutron Scattering Lab, Tokai, Ibaraki 3191106, Japan
[3] High Energy Accelerator Res Org, Inst Mat Struct Sci, Photon Factory, Tsukuba, Ibaraki 3050801, Japan
[4] Mac Sci Co Ltd, Kohoku Ku, Yokohama, Kanagawa 2220033, Japan
关键词
D O I
10.1107/S0021889800009286
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A synchrotron radiation X-ray powder diffractometer for samples of very small amount has been developed to collect high-quality diffraction patterns under extreme conditions, i.e. at low temperature and/or high pressure. A new cylindrical imaging plate (CIP) is used as a detector, in addition to a conventional flat-type imaging plate (FIP). By using the CIP system, the diffraction data in a diffraction angle range -44 less than or equal to 2 theta less than or equal to 122 degrees are collected with a dynamic range of about 10(6). The alignment of the diffractometer, measurement and analysis are automatically operated by a workstation. A performance test shows that the CIP system has spatial resolution of about 0.07 degrees with a dynamic range of 10(6). The diffraction pattern of a standard sample of Si measured by the CIP system has high quality; the refinement of the structure reaches R-w = 3.68% even in the case of a small amount of sample (about 2 mu g) and a short exposure time (60 s). Examples of experiments at low temperatures under ambient and high pressures are also presented.
引用
收藏
页码:1241 / 1245
页数:5
相关论文
共 11 条
[1]   LASER-STIMULATED LUMINESCENCE USED TO MEASURE X-RAY-DIFFRACTION OF A CONTRACTING STRIATED-MUSCLE [J].
AMEMIYA, Y ;
WAKABAYASHI, K ;
TANAKA, H ;
UENO, Y ;
MIYAHARA, J .
SCIENCE, 1987, 237 (4811) :164-168
[2]   IMAGING PLATES FOR USE WITH SYNCHROTRON-RADIATION [J].
AMEMIYA, Y .
JOURNAL OF SYNCHROTRON RADIATION, 1995, 2 :13-21
[3]  
[Anonymous], 1993, RIETVELD METHOD
[4]   Structural phase transition in the ammoniated alkali C60 compound (NH3)K3C60 [J].
Ishii, K ;
Watanuki, T ;
Fujiwara, A ;
Suematsu, H ;
Iwasa, Y ;
Shimoda, H ;
Mitani, T ;
Nakao, H ;
Fujii, Y ;
Murakami, Y ;
Kawada, H .
PHYSICAL REVIEW B, 1999, 59 (06) :3956-3960
[5]  
KIM YI, 1994, J CERAM SOC JPN, V102, P401
[6]  
Menoni C. S., 1984, High Temperatures - High Pressures, V16, P119
[7]   A NEW TYPE OF X-RAY AREA DETECTOR UTILIZING LASER STIMULATED LUMINESCENCE [J].
MIYAHARA, J ;
TAKAHASHI, K ;
AMEMIYA, Y ;
KAMIYA, N ;
SATOW, Y .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3) :572-578
[8]   Structure and phase transition of fullerene C76 crystal studied by x-ray scattering [J].
Nakao, H ;
Fujii, Y ;
Watanuki, T ;
Ishii, K ;
Suematsu, H ;
Kawada, H ;
Murakami, Y ;
Kikuchi, K ;
Achiba, Y ;
Maniwa, Y .
JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 1998, 67 (12) :4117-4123
[9]   Pressure-induced phase transition in NaV2O5 at low temperature [J].
Ohwada, K ;
Nakao, H ;
Nakatogawa, H ;
Takesue, N ;
Fujii, Y ;
Isobe, M ;
Ueda, Y ;
Wakabayashi, Y ;
Murakami, Y .
JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 2000, 69 (03) :639-642
[10]   APPLICATION OF AN IMAGING PLATE TO HIGH-PRESSURE X-RAY STUDY WITH A DIAMOND ANVIL CELL (INVITED) [J].
SHIMOMURA, O ;
TAKEMURA, K ;
FUJIHISA, H ;
FUJII, Y ;
OHISHI, Y ;
KIKEGAWA, T ;
AMEMIYA, Y ;
MATSUSHITA, T .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01) :967-973