Immunoassay for the determination of morphine-3-glucuronide using a surface plasmon resonance-based biosensor

被引:58
作者
Dillon, PP [1 ]
Daly, SJ
Manning, BM
O'Kennedy, R
机构
[1] Dublin City Univ, Sch Biotechnol, Dublin 9, Ireland
[2] Dublin City Univ, NCSR, Dublin 9, Ireland
关键词
morphine-3-glucuronide; surface plasmon resonance; biosensor; inhibitive assay;
D O I
10.1016/S0956-5663(02)00182-3
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Polyclonal antibodies were produced for the development of competitive ELISA's and surface plasmon resonance (SPR)-based BIAcore inhibition assays for the detection of morphine-3-glucuronide (M3G, the main metabolite of heroin and morphine). A conjugate consisting of M3G and ovalbumin was produced and used for the generation of antibodies, for the coating of immunoplates and for immobilisation onto BlAcore chips. Competition ELISA's were developed in PBS and urine to characterise the antibodies ability to recognise free M3G. SPR-based inhibition immunoassays on BlAcore were developed. The regeneration of the surface of a chip immobilised with conjugate following antibody binding, essential for the development of inhibition assays was investigated. Regeneration of the conjugate-coated surface was optimised for both polyclonal antibodies resulting in binding-regeneration capacities of approximately 60 cycles for one antibody and 50 cycles for the second antibody. The inhibition assays developed in urine had ranges of detection of 762-24,400 (antibody 1) and 976-62,500 pg ml(-1) (antibody 2). The inter-day coefficients of variation for the assays ranged from 1.48 to 11.24%. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:217 / 227
页数:11
相关论文
共 19 条
[1]  
COYLE DE, 1987, OPIATES METHODS CLIN, P409
[2]   Development of surface plasmon resonance-based immunoassay for aflatoxin B1 [J].
Daly, SJ ;
Keating, GJ ;
Dillon, PP ;
Manning, BM ;
O'Kennedy, R ;
Lee, HA ;
Morgan, MRA .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2000, 48 (11) :5097-5104
[3]   Fatal heroin 'overdose': A review [J].
Darke, S ;
Zador, D .
ADDICTION, 1996, 91 (12) :1765-1772
[4]  
GOUGH TA, 1991, ANAL DRUGS ABUSE
[5]   AN AMPEROMETRIC OPIATE ASSAY [J].
HOLT, PJ ;
STEPHENS, G ;
BRUCE, NC ;
LOWE, CR .
BIOSENSORS & BIOELECTRONICS, 1995, 10 (6-7) :517-526
[6]   Bioluminescent assay for heroin and its metabolites [J].
Holt, PJ ;
Bruce, NC ;
Lowe, CR .
ANALYTICAL CHEMISTRY, 1996, 68 (11) :1877-1882
[7]  
JONSSON U, 1991, BIOTECHNIQUES, V11, P620
[8]   Immunoassay for the determination of 7-hydroxycoumarin in serum using 'real-time' biosensor analysis [J].
Keating, GJ ;
Quinn, JG ;
O'Kennedy, R .
ANALYTICAL LETTERS, 1999, 32 (11) :2163-2176
[9]   High-performance liquid chromatographic determination of morphine and its 3- and 6-glucuronide metabolites by two-step solid-phase extraction [J].
Meng, QC ;
Cepeda, MS ;
Kramer, T ;
Zou, H ;
Matoka, DJ ;
Farrar, J .
JOURNAL OF CHROMATOGRAPHY B, 2000, 742 (01) :115-123
[10]   RIDING THE EVANESCENT-WAVE [J].
PANAYOTOU, G ;
WATERFIELD, MD ;
END, P .
CURRENT BIOLOGY, 1993, 3 (12) :913-915