Feasibility of Raman spectroscopy as PAT tool in active coating

被引:63
作者
Mueller, Joshua [1 ]
Knop, Klaus [1 ]
Thies, Jochen [2 ]
Uerpmann, Carsten [3 ]
Kleinebudde, Peter [1 ]
机构
[1] Univ Dusseldorf, Inst Pharmaceut & Biopharmaceut, D-40225 Dusseldorf, Germany
[2] LB Bohle Maschinen Verfahren GmbH, Ennigerloh, Germany
[3] Kaiser Opt Syst Inc, Ecully, France
关键词
Active coating; in-line measurement; multivariate curve resolution; process analytical technology; Raman spectroscopy; tablet coating; NEAR-INFRARED SPECTROSCOPY; FILM-COATED TABLET; PHARMACEUTICAL TABLETS; THICKNESS;
D O I
10.3109/03639040903225109
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Background: Active coating is a specific application of film coating where the active ingredient is comprised in the coating layer. This implementation is a challenging operation regarding the achievement of desired amount of coating and coating uniformity. To guarantee the quality of such dosage forms it is desirable to develop a tool that is able to monitor the coating operation and detect the end of the process. Method: Coating experiments were performed at which the model drug diprophylline is coated in a pan coater on placebo tablets and tablets containing the active ingredient itself. During the active coating Raman spectra were recorded in-line. The spectral measurements were correlated with the average weight gain and the amount of coated active ingredient at each time point. The developed chemometric model was tested by monitoring further coated batches. Furthermore, the effects of pan rotation speed and working distance on the acquired Raman signal and, hence, resulting effect of the chemometric model were examined. Results: Besides coating on placebo cores it was possible to determine the amount of active ingredient in the film when coated onto cores containing the same active ingredient. In addition, the method is even applicable when varying the process parameters and measurement conditions within a restricted range. Conclusion: Raman spectroscopy is an appropriate process analytical technology too.
引用
收藏
页码:234 / 243
页数:10
相关论文
共 15 条
[1]  
ANDERSSON M, 1999, J PHARM BIOMED ANAL, V13, P1273
[2]  
[Anonymous], 2004, Food and Drug Administration Guidance for industry PATa framework for innovative pharmaceutical development, manufacturing and quality Assurance
[3]   Use of near-infrared spectroscopy to evaluate an active in a film coated tablet [J].
Buchanan, BR ;
Baxter, MA ;
Chen, TS ;
Qin, XZ ;
Robinson, PA .
PHARMACEUTICAL RESEARCH, 1996, 13 (04) :616-621
[4]  
El Hagrasy A., 2006, AM PHARM REV, V9, P40
[5]  
El Hagrasy A., 2006, Journal of Pharmaceutical Innovation, V1, P37, DOI [10.1007/BF02784879, DOI 10.1007/BF02784879]
[6]  
Fricke S, 2006, Feste perorale Arzneiform zur Kontrazeption, die Dienogest und Ethinylestradiol enthalt, Patent No. [1690529, EP1690529A1.]
[7]   Raman spectroscopy of coated pharmaceutical tablets and physical models for multivariate calibration to tablet coating thickness [J].
Kauffman, John F. ;
Dellibovi, Marybeth ;
Cunningham, Charles R. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (01) :39-48
[8]   Direct, non-destructive quantitative measurement of an active pharmaceutical ingredient in an intact capsule formulation using Raman spectroscopy [J].
Kim, Jaejin ;
Noh, Jaegeun ;
Chung, Hoeil ;
Woo, Young-Ah ;
Kemper, Mark S. ;
Lee, Youngil .
ANALYTICA CHIMICA ACTA, 2007, 598 (02) :280-285
[9]   New reliable Raman collection system using the wide area illumination (WAI) scheme combined with the synchronous intensity correction standard for the analysis of pharmaceutical tablets [J].
Kim, Minjung ;
Chung, Hoeil ;
Woo, Youngah ;
Kemper, Mark .
ANALYTICA CHIMICA ACTA, 2006, 579 (02) :209-216
[10]   DETERMINATION OF FILM-COATED TABLET PARAMETERS BY NEAR-INFRARED SPECTROSCOPY [J].
KIRSCH, JD ;
DRENNEN, JK .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1995, 13 (10) :1273-1281